Gardena 1489 Руководство по эксплуатации - Страница 4

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Водяной насос Gardena 1489. Gardena 1489 9 страниц. Deep well pump
Также для Gardena 1489: Руководство по эксплуатации (10 страниц)

Gardena 1489 Руководство по эксплуатации
For Art. 1499 only:
Before putting the pump into operation or switching it on,
Bleeding:
please note: When first put into operation, the pump takes
about 60 seconds to vent after submersion in the water.
v Put the pump into operation only after this 60-second
submersion phase.
Once the pump has been put into operation, the end of the bleed ing
operation is indicated by a jet of water exiting the bleed openings.
For Art. 1499 only:
The pump pumps and switches off automatically as soon as
Automatic mode:
no more water is drawn. Due to the check valve, the pressure is
maintained in the hose until water is drawn via the hose.
When water is drawn via the hose (the pressure in the hose falls
below 3.5 bar), the pump switches on automatically.
For Art. 1499 only:
The pump switches off automatically when there is no fluid
Dry run protection
pumped (the pump operates in cycles 30 secs. on – 5 secs. off
(flow control):
(4x). This cycle is repeated in 1 hr, 5 hrs, 24 hrs, 24 hrs ... ).
As soon as the inlet filter of the pump is again submersed at least
15cm in the water, the pump is ready to operate again.
For Art. 1499 only:
The flow control switches off automatically as soon as no more
Flow control:
water is drawn. In the event of leakage on the pressure side
(e. g. leaking pressure hose or tap) switches the pump on and off at
short intervals. If the pump is switched on and off more frequently
than 7 x in 2 min. (with a leakage < 200 l/hr), the pump switches off
completely. When the leakage on the pressure side is eliminated,
the pump must be unplugged and plugged in again in order to be
operational again.
For Art. 1499 only:
The built-in non-return valve prevents the water flowing back
Non-return valve:
through the pump.

5. Putting into Storage

Storage:
The storage location must not be accessible to children.
v Store the pump away from frost before the first frost sets in.
Disposal:
The product must not be added to normal household waste.
(in accordance with
It must be disposed of in line with local environmental regulations.
RL2002/96/EC)

6. Maintenance

Clean priming area:
0
1. Unscrew both screws
2. Clean priming area of the pump and inlet filter
3. Fix inlet filter
with the two screws
!
12
DANGER! Electric shock!
There is a risk of injury from electric
shocks.
V Disconnect the Deep Well Pump from the mains
power supply before carrying out maintenance.
0
and remove the inlet filter
q
q
.
q
around the priming area again and screw tight
0
.

7. Trouble-Shooting

Fault
Pump is running,
but doesn't deliver.
Pump doesn't start or
suddenly stops during
operation.
Pump runs, but output
suddenly decreases.
For any other malfunctions please contact the GARDENA service department.
Repairs must only be carried out by GARDENA service departments or specialist
dealers authorised by GARDENA.
.
DANGER! Electric shock!
There is a risk of injury from electric
shocks.
V Before eliminating faults, disconnect the Deep
Well Pump from the mains power supply.
Possible cause
Remedy
Air cannot escape as the
v Open pressure line
pressure line is closed.
(e. g. bent pressure hose).
Priming area blocked.
v Disconnect mains plug
and clean priming area
(see 6. Maintenance).
When starting the pump,
v Immerse pump deeper
water height falls below the
(observe minimum water
min. water level.
level: see 9. Technical Data).
Non-return valve blocked.
v Art. 1499:
Contact GARDENA Service.
Thermal protection switch
v Disconnect mains plug
switched pump off due to
and clean priming area
overheating.
(see 6. Maintenance).
Observe max. media
temperature (35 °C).
Power supply interrupted.
v Check fuses and electrical
plug-in connections.
Dirt particles are trapped in
v Disconnect mains plug
priming area.
and clean priming area
(see 6. Maintenance).
Priming area blocked.
v Disconnect mains plug
and clean priming area
(see 6. Maintenance).
For Art. 1499 only: Lack of
The pump is only operational
water: Dry run protection
when it is submerged at least
switched the pump off due to
15 cm.
insufficient water level.
v Submerge pump at least
15 cm in water.
13