Gardena 9034 Руководство по эксплуатации - Страница 7
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Водяной насос Gardena 9034. Gardena 9034 17 страниц. Clear water submersible pump/ dirty water submersible pump
Также для Gardena 9034: Руководство по эксплуатации (16 страниц)
The manual operation remains active even after discon-
necting the power supply.
To stop manual operation, disconnect the pump from the
mains and take it out of the water. Connect the pump to
the power supply again and keep sensor field
until it is acknowledged by double flashing of all LEDs.
Now you are again in automatic mode.
Only operate the manual mode under supervision.
Time-limited manual operation:
In time-limited manual operation, the sensor fields are
deactivated for 10 minutes. The pump then runs for
10 minutes and then switches off automatically.
ß
v Keep the sensor fields
S7
double flashing of all LED's has acknowledged the
input.
All LEDs will light up and within 10 seconds all LEDs will
switch off one after the other. The pump starts.
After 10 minutes the pump automatically switches back
to automatic operation.
4. MAINTENANCE
DANGER! Risk of physical injury!
Injury when the product starts accidentally.
v Disconnect the product from the mains before
you maintain the product.
To clean the pump:
DANGER! Risk of physical injury!
Risk of injury and risk of damage to the
product.
v Do not clean the product with a water jet
(in particular high-pressure water jet).
v Do not clean with chemicals including petrol or
solvents. Some can destroy critical plastic parts.
5. STORAGE
To put into storage:
The pump is not frost-proof!
The product must be stored away from children.
1. Disconnect the pump from the mains.
2. Turn the pump upside down until no more water runs
out.
3. Clean the pump (see 4. MAINTENANCE).
4. Store the pump in a dry, enclosed and frost-free place.
ß
pressed
S9
ß
and
pushed until the
S8
After disconnecting the power supply, the pump auto-
matically switches back to automatic operation.
To return to the automatic mode again, push and hold the
ß
ß
2 sensor fields
and
simultaneously until the double
S7
S8
flashing of all LEDs has acknowledged the input.
Flat suction / normal operation (only for the clear
water submersible pumps) [ Fig. O2 ]:
Normal operation:
Recommended operating mode for maximum pumping
capacity and grain size up to 5 mm, especially in automatic
mode.
v Fold the 3 folding feet
(F)
Flat suction:
The residual water height of approx. 1 mm is only achieved
with flat suction in manual operation. Please note that in
this mode the delivery and suction capacity is reduced.
(F)
v Fold the 3 folding feet
v Clean the surface of the pump with a damp cloth.
To flush the pump:
After pumping water containing chlorine, detergents or
heavily soiled water, the pump must be flushed.
1. Pump lukewarm water (max. 35 °C), possibly adding
a mild cleaning agent (e. g. detergent) until the pumped
water runs clear.
2. Remove residuals according to the waste disposal laws
applicable in your area.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal
household waste. It must be disposed of in line
with local environmental regulations.
IMPORTANT!
v Dispose of the product through or via your municipal
recycling collection centre.
inwards.