Cosel FETA2500B Руководство по эксплуатации - Страница 4
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Источник питания Cosel FETA2500B. Cosel FETA2500B 9 страниц.

2.6 Thermal Protection
¡ A thermal protection circuit is built-in.
The thermal protection circuit may be activated under following
conditions and shut down the output.
1 When a current and a temperature continue to exceed the val-
ues determined by the derating curve.
2 When a fan stops or air fl ow weakens by intake port or exhaust
port is blocked.
If the thermal protection circuit is activated, shut off the input volt-
age and eliminate all the overheating conditions. To recover the
output voltage, have enough time to cool down the unit before
turning on the input voltage again.
2.7 Output Voltage Adjustment Range
¡ To increase an output voltage, turn a built-in potentiometer clock-
wise. To decrease the output voltage, turn it counterclockwise.
¡ The power supplies have an external output voltage control func-
tion. The output voltage can be adjusted within a 110% range
from 90% by changing the voltage between the terminal TRM and
the terminal COM on CN1/CN2. You can decrease the voltage by
drawing a current from the TRM terminal.
You can calculate the output voltage in this case from formula 1
below.
Please note that the formula 1 gives you only an estimate.
Please contact us if you need accurate numbers.
Please do not apply negative Voltage to TRM terminal.
There is more than one method to adjust the output voltage, in-
cluding the methods to use external resistors and external power
supplies. Since each method has different characteristic, please
contact us for details.
The voltage between
TRM and COM
Output voltage =
2.5 [V]
2.8 Output Ripple and Ripple Noise
¡ Output ripple noise may be infl uenced by measurement environ-
ment, measuring method Fig.2.1 is recommended.
+Vout
-Vout
Oscilloscope
Bw:500MHz
C
Aluminum electrolytic capacitor 22μF
1 :
Fig.2.1 Measuring method of Ripple and Ripple Noise
Remarks :
When GND cable of probe with fl ux of magnetic force from power
supply are crossing, ripple and ripple noise might not measure
correctly.
Please note the measuring environment.
AC-DC Power Supplies Enclosed type
X rated output voltage- - -1
C
+
1
Load
150mm
Differential probe
Instruction Manual
Bad example
Fig.2.2. Example of measuring output ripple and ripple noise
2.9 Remote ON/OFF
¡ These models have a remote ON/OFF function.
¡ You can operate the remote ON/OFF function by sending signals
to CN1/CN2. Please see Table 2.1 and Table 2.2 for specifica-
tions and Fig.2.3 for connecting examples.
¡ Please note the followings when using the remote ON/OFF func-
tion.
1The output stops when a current fl ows to RC.
2The current fl own to RC is a 20mA max.
3When the output voltage is turned off through the remote ON/OFF
circuit, the built-in fan slows down.
4If the output voltage is turned off through the remote ON/OFF
circuit, the WRN signals and the PG signals keep "Low".
5Description in this section is based on the assumption that you
will use one unit alone. If you are planning to use the units
in parallel operation or use multiple units for a single system,
please check necessary voltage and current values.
¡ Please wire carefully. If you are wrongly, the internal components
of a unit may be damaged.
¡ Remote ON/OFF circuits (RC and RCG) are isolated from input,
output, FG, AUX, WRN and PG.
Table 2.1 Specifi cations of remote ON/OFF (RC-RCG)
Output voltage
ON
L level (0 to 0.5V) or open
OFF
H level (4.5 to 12.5V)
Table 2.2 Specifi cations of remote ON/OFF (Case of Fig.2.3)
Connection method
Fig.2.3 (a)
Power ON
(0.1mA max)
Power OFF
Base pin
RCG
(a)
(b)
AUX
Ri=780W
Ri=780W
*1
Ra
RC
12V
12V
typ
typ
Vcc
RCG
SW
AUXG
Fig.2.3 Examples of connecting remote ON/OFF circuit
150mm
Good example
Between RC and RCG
Fig.2.3 (b)
Fig.2.3 (c)
SW open
SW close
(0.5V max)
SW close
SW open
(3mA min)
(0.1mA max)
AUXG
RCG, AUXG
(c)
Rb=1kW
AUX
AUX
Ri=780W
RC
RC
12V
typ
RCG
RCG
SW
AUXG
AUXG
FETA-7
FETA
SW