A&E Trading TM262 Инструкции по монтажу - Страница 8
Просмотреть онлайн или скачать pdf Инструкции по монтажу для Внутренняя отделка A&E Trading TM262. A&E Trading TM262 9 страниц.
Error messages in the display + reset (first use)
TMU 30
Code
Description
A0
SC-Reset OK
A63
THD-Display overflow
A64
Forced reset
A65
Child safety device
A66
(Extra) safety handswitch
A67
(Extra) safety handswitch
A69
Safety strip not connected
A6F
Travel monitoring
A70
Hall-sensor; no signaal
A71
Hall-sensor; wrong direction of motor
A72
Motor missing / no connection
A73
Motor missing / no current
nd
A79
Link missing 2
controlbox
nd
A7A
Link missing 2
controlbox
nd
A7B
Link missing 2
controlbox
nd
A7C
Link missing 2
controlbox
AC9
Duty cycle
ACA
Overheat
A07
Motor(s) overheat
A&E Trading b.v. | Mounting Instructions TM262
Reset the system for first use;
Keep the 'up' and 'down' button pressed until the table reaches is't lowest
position and the controlbox gives an acoustic signal.
Solution
The controlbox must be initialised. Keep
the 'up' and 'down' button pressed until
the table reaches is't lowest position and
the controlbox gives an acoustic signal.
Deactivate the child safety device by
pressing the 'M' button for 10 seconds.
A second (release) manual switch must be
connected.
Connect the safety strip aan.
The controlbox has detected an error
when moving the table.
The table may have seized or be
overloaded:
-
Remove the defect and then
move the table briefly in the
opposite direction.
A motor is not properly conected tot he
controlbox:
-
The
controlbox
initialised. Keep the 'up' and
'down' button pressed until the
table reaches is't lowest position
and the controlbox gives an
acoustic signal.
Contact your supplier.
Contact your supplier.
The drives were operated longer than
permitted. In order to protect the
controlbox from overheating operation is
blocked fort he next few minutes. After
this time the drives can be moved again.
must
be
8