The burner is only partly
glowing
The burner makes a lot
of noise after ignition or
after several minutes
The burner do not work
at minimum position
Heater will not attain the
desired temperature
Declaration of conformity
We, Alke B.V., located in Scherpenzeel, The Netherlands, hereby declare that the Global series, marked
on their dataplates with CE and with CE approval/production supervision by Kiwa (number 0063) are in
compliance with the following EU legislation:
-
Directive on appliances burning gaseous fuels (GAD) 2009/142/EC (ex 90/396/EEC)
-
Regulation on appliances burning gaseous fuels (GAR) 2016/426/EU
-
Low Voltage Directive (LVD) 2014/35/EU (models with electric components)
-
EMC Directive (EMC) 2014/30/EU (models with electric components)
Scherpenzeel, 01-09-2017
Adri van Alphen
President
Version: Sept 2017
•
Wrong gas or pressure is used. Check data plate with the gas supply
•
Check if the injector or venturi are blocked or dirty
•
Check the injector and venture size with the table
•
Check if pipe sizes or gas hoses have sufficient capacity
•
Check the setting of the thermostat
•
Valve (35) dual injection model (Di) is blocked
•
Wrong gas is used. Check data plate with the gas supply
•
Check if the inner globe is broken or damaged so the flame burns
inside the venturi tube
•
A zoom noise of the EID2G is created by magnetic fields and lasts only
30 seconds. Not harmful. Temperature dependent. Turn the EID2G in
another position
•
Gas pressure is not correct. Check the gas pressure with the data plate
•
Wrong gas is used. Check data plate for the correct gas supply
•
Check the size of the venturi and injector with the table
•
Sensor or wire thermostat (T) is broken
•
Thermostat (T) valve adjusting mechanism is blocked
•
By-pass hole thermostat (T) or solenoid valve (S) is blocked
•
Injector (partly) blocked
•
Centre hole dual injector (Di) is blocked
•
Check if the thermocouple has the proper depth in the burner,
measured on the top plate (Global 5 = 25mm, Global 10 = 22 mm)
•
There is insufficient heat in the building for heat loss (i.e., not enough
brooders).
•
The thermostat (T) sensing bulb is incorrectly placed
•
The thermostat (T) is out of calibration or broken
•
The solenoid valve (S) is not functioning
•
One of the two holes of the dual injector (Di) is blocked
•
Injector partly blocked