alkitronic CLS2/300 Руководство по эксплуатации и техническому обслуживанию - Страница 5

Просмотреть онлайн или скачать pdf Руководство по эксплуатации и техническому обслуживанию для Инструменты alkitronic CLS2/300. alkitronic CLS2/300 12 страниц. Compact torque multiplier

1.

Safety instructions

1.1

Obligations of the operator

The user is obliged to read these operating and maintenance
instructions before carrying out any operation or service. al-
kitronic® torque multiplier operations may only be performed
by persons who are familiar with the purpose, consequences
and exact execution.
The user must not be impaired in any way, such as through
drugs, alcohol and medication.
1.2

Intended use

alkitronic® torque multiplier are suitable for continuously ro-
tating tightening and loosening of heavy screw connections.
Any other use, e.g. as a stirring or drilling machine, can cause
damage to the device and the operator. The torque multipli-
ers must not be subjected to external mechanical forces that
could lead to deformation. Other types of use not listed here
require the approval of alki TECHNIK GmbH.
If you have questions about safety measures and areas of ap-
plication, your alkitronic® Partner will be happy to help you.
Incorrect operation, improper use, operation by
unqualified personnel can cause serious personal
injury and property damage.
The user is responsible to third parties in the work
area.
2.

Operation

Depending on the work environment and field of application
for the alkitronic® torque multiplier, local regulations for the
wearing of body protection (eg safety shoes, helmet, etc.)
may apply.
Failure to comply with such regulations can result
in serious bodily injury (e.g. crushing, head inju-
ries from flying metal parts). When operating the
alkitronic® torque multiplier wearing of hearing
protection is mandatory. In continuous operation,
the handle housing cools down greatly. Wearing
gloves is therefore recommended.
2.1

Commissioning

Depending on the field of applciation, standard nuts / con-
nectors, special torque transducers or adapters are required
for tightening and loosening screw connections (available as
accessories). The standard nuts / connectors are attached to
the output square and secured. Exchange see also Service,
section 3.1.
Before the compressed air is connected, the multiplier must
be prepared for the process:
Pneumatic Torque Multiplier
5
Conducting a security check for correct fit of the adapter
Check for possible damages of the DMAs or adapter
In case of damage, replace immediately - do not continue
working. Only use original alkitronic® accessories or spare
parts!
2.2

Preparing for use

4
5
alkitronic® DMA
Torque reaction absorber
• Place the alkitronic® CL multiplier on a flat surface
• Put support foot / DMA (1) on the gearing (4)
• Fix the standard nut / connector (2) / (3) to the square
shaft (5)
• Insert locking pin (7), secure with rubber ring (6)
or screw in the locking screw (8)
6
2
alkitronic®
STACO
1
Standard
nut
7
2
alkitronic® STACO
Standard nut
8
3
alkitronic® STABI
Standard connector