alkitronic EFCip Руководство по эксплуатации и техническому обслуживанию - Страница 13

Просмотреть онлайн или скачать pdf Руководство по эксплуатации и техническому обслуживанию для Компьютерное оборудование alkitronic EFCip. alkitronic EFCip 16 страниц. Electric torque multiplier

8.3.

Taking out of operation

In case that the alkitronic® electric torque multiplier
is stored for a prolonged period of time:
Store the tool cleaned in a closeable dry room, out
of the reach of children. Avoid excessive exposure
to heat and moisture. Moving/rotating tool parts
are to be preserved against Oxidation.
Note additionally item 8.2 Storage
8.4

Maintenance intervals

The alkitronic® electric torque multiplier is an ex-
tremely efficient and robust product. Nevertheless
to ensure lifetime and performance for years, a
regular maintenance is necessary (Performance-
Check, Motor-Check, Safety-Check, Calibration-
Service).
Maintenance periode
The torque multiplier must be submitted at least
once a year for inspection.
After high stresses/loads or also hours of operation
a calibration and ser vicing must be carried out in
shorter periodes. In this case a service warning ap-
Upon unusual gear or bearing noises, a lubrication
of the transmission parts is urgently recommended
in order to exclude consequential damage.
In the event of repairs the alkitronic® torque mul-
tiplier must be sent to the appropriate alkitronic®
Partner or directly to alki Technik GmbH in original
package.
.
9.

Technical Notes

Notes regarding the operation of mobile genera-
tors:
For proper operation it must be ensured that the
power output of a mobile generator is at least in
accordance with the power input of the alkitronic®
torque multiplier.
We recommend the use of regulated Mobile
Generators.
Power output min. 1.5 kW upon operation of one
alkitronic® torque multiplier.
electric torque multipliers
pears in the display to remind
the user. Acknowledge the
message with the "M" button.
From this time on the informa-
tion is shown at every restart of
the torque multiplier.
Automatic or Inverter Regulations deliver a con-
stant output voltage as well as a constant output
current regardless of voltage drops , any spikes,
the load or heavy load fluctuations.
Operating multiple appliances at one mobile gen-
erator at the same time the power consumption of
all appliances must be considered!
Unregulated output voltage impairs operation
and may damage the electronics of the alkitronic®
torque multiplier extensively or even cause the
equipment to shut down. Besides, in case of dam-
age, warranty claims are at risk. Consistent power
output without spikes is extremely important for
safety in operation.

10. Acoustic Emission and Vibration

Sound pressure levels were measured for different work
cycles, with the sensor positioned at a distance of 1 m to the
geometric centre of the machine.
Sound pressure level at max. idling speed:
Models EFCip.../ ECWip... 68 - 72 dB(A).
Vibration:
becomes moderate just prior to reaching the pre-set torque.

11. Declaration of Conformity

On our own responsibility hereby declares alki Technik GmbH
that the alkitronic® electric torque multipliers identified by
Type ECip-N...., EFCip..../ECWip.... and Serial number -71.....,
-81....., -91....., -02....., -12....., -22....., -32..... meet all relevant
requirements of directives
2006/42/EG, 2014/35/EU, 2011/65/EU, 2014/53/EU,
2014/30/EU and Norms
DIN EN 61000-6-2, DIN EN 61000-6-4, ETSI EN 301
489-17, DIN EN 61800-5-1, DIN EN 50581:2012
DIN EN 60034-1, ETSI EN 300 328, DIN EN 60745-
1:2010-01, DIN EN 60745-2-2:2010.
2017-06-30
Techn. documents at alki Technik GmbH, Unterlettenweg 4,
85051 Ingolstadt / Germany.

12. Appendix

- Technical info, Replacement of Power Cord Plug, page 14
- Technical data, page 15
©alki TECHNIK Gmbh/ GBA EFCip/2/29-09-20/4Pdesign
Materials and specifications are subject to change without notice.
13
Alexander Kipfelsberger,
Managing director