Garmin GHP Reactor Hydraulic Руководство по установке - Страница 10

Просмотреть онлайн или скачать pdf Руководство по установке для Морское оборудование Garmin GHP Reactor Hydraulic. Garmin GHP Reactor Hydraulic 15 страниц.

Garmin GHP Reactor Hydraulic Руководство по установке

Advanced Configuration Settings

You can run the autotune process, calibrate the compass, and
define north on the autopilot without running the wizards. You
can also define each setting individually, without running the
configuration processes.
Running the Automated Configuration Processes Manually
1
Enable Dealer Mode
(Enabling Dealer
2
From the heading screen, select Menu > Setup > Dealer
Autopilot Setup.
3
Select an automated process:
• Select Compass Setup > Calibrate Compass to start the
compass calibration procedures
Compass).
• Select Compass Setup > Set North to start the
procedures to define north
• Select Autopilot Tuning > Autotune to start the
automatic autopilot tuning procedures
Autotune
Procedure).
4
Follow the on-screen instructions.
Defining Individual Configuration Settings Manually
Configuring certain configuration settings may require you to
modify other settings. Review the "Detailed Configuration
Settings" section
(Detailed Configuration
modifying any settings.
1
Enable Dealer Mode
(Enabling Dealer
2
From the heading screen, select Menu > Setup > Dealer
Autopilot Setup.
3
Select a setting category.
4
Select a setting to configure.
Descriptions of each setting are available in the appendix
(Detailed Configuration
5
Configure the value of the setting.
Appendix
NMEA 0183 Connection Diagrams
These wiring diagrams are examples of different situations you
may encounter when connecting your NMEA 0183 device to the
helm control.
NMEA 0183 Connection Considerations
• The installation instructions provided with your NMEA 0183
compatible device should contain the information you need to
identify the transmitting (Tx) and receiving (Rx) A (+) and B
(-) wires.
• When connecting NMEA 0183 devices with two transmitting
and two receiving wires, it is not necessary for the NMEA
2000 bus and the NMEA 0183 device to connect to a
common ground.
• When connecting a NMEA 0183 device with only one
transmitting (Tx) wire or with only one receiving (Rx) wire, the
NMEA 2000 bus and the NMEA 0183 device must be
connected to a common ground.
Two-Way NMEA 0183 Communication
10
Configuration).
(Calibrating the
(Setting
North).
(Performing the
Settings) prior to
Configuration).
Settings).
NMEA 2000 network (provides power to the helm control)
12 Vdc power source
Helm control
NMEA 0183-compatible device
Wire Helm Control Wire Color —
Function
N/A
N/A
Blue — Tx/A (+)
White — Tx/B (-)
Brown — Rx/A (+)
Green — Rx/B (-)
NOTE: When connecting a NMEA 0183 device with two
transmitting and two receiving lines, it is not necessary for the
NMEA 2000 bus and the NMEA 0183 device to connect to a
common ground.
Only One Receiving Wire
If your NMEA 0183-compatible device has only one receiving
wire (Rx), it must be connected to the blue wire (Tx/A) from the
helm control, and the white wire (Tx/B) from the helm control
must remain unconnected.
NMEA 2000network (provides power to the helm control)
12 Vdc power source
Helm control
NMEA 0183-compatible device
Wire Helm Control Wire Color —
Function
N/A
N/A
Blue — Tx/A (+)
White — unconnected
Brown — Rx/A (+)
Green — Rx/B (-)
NOTE: When connecting a NMEA 0183 device with only one
receiving (Rx) line, the NMEA 2000 bus and the NMEA 0183
device must be connected to a common ground.
Only One Transmitting Wire
If your NMEA 0183-compatible device has only one transmitting
wire (Tx), it must be connected to the brown wire (Rx/A) from the
helm control, and the green wire (Rx/B) from the helm control
must be connected to NMEA 0183 ground.
NMEA 0183-Compatible
Device Wire Function
Power
NMEA 0183 ground
Rx/A (+)
Rx/B (-)
Tx/A (+)
Tx/B (-)
NMEA 0183-Compatible
Device Wire Function
Power
NMEA 0183 ground
Rx
N/A
Tx/A (+)
Tx/B (-)