Wall Mounted High-Heat 9, 12 and 15,000 BTU Systems
SYSTEMS 9RLS2H, 12RLS2H, 15RLS2H
Energy Saving Program
ESP senses when you leave a room
and 20 minutes later, set temperature is increased
by 4°F when cooling and reduced by 8°F when
heating. When you come back to the room, it
returns to previous operating mode. This feature
can be deactivated if chosen.
High Performance Heating
Heating capacity at low outdoor temperatures was
improved by adopting a large heat exchanger, a
high capacity compressor, and a base heater for the
outdoor unit. Rated heating capacity is maintained up
to 20°F. RLS2H models can operate down to -15°F.
Base Freeze Prevention
Equipped with a base heater that
prevents condensate from freezing
Cultivated base design discharges
melted water through many holes.
Without a heater, freezing
condensate can cause noise,
damage to fan blade, condenser,
and system performance
Fujitsu RLS2H
Competitor
Drain hole is not filled,
Freezing where there
no freezing of base
is no heater
Condition: Indoor temp. of 68°FDB / outdoor temp. of 5°FDB,
Heating mode, High airflow volume . Operation for 24 hours.
Optional Accessories
Wired Remote Controller: UTY-RVNUM
Backlit and includes room temperature!
Wired Remote Controller: UTY-RNNUM
Simple Remote Controller: UTY-RSNUM
Communication Kit: UTY-TWBXF
Federal Tax Credit Qualified
$
See Page 9 for details
Systems 9RLS2H and 12RLS2H only.
Min.~Max. Cooling
Min.~Max. Heating
Clg. Operating Range °F(°C)
Htg. Operating Range °F(°C)
Moisture Removal
Voltage/Frequency/Phase
Recommended Fuse Size
Drain Holes
Base Heater
Outdoor Fan Speed
Competitor
Outdoor Noise Level
Current
Power Use
Drain hole is closed,
large freezing of base
Combined Min. Lgth
Combined Max. Lgth
Conn. Pipe Diameter
Dimensions: Height
9RLS2H
Heat Pump
9,000
Nominal Cooling
BTU/h
BTU/h
3,100~12,000
Nominal Heating
BTU/h
12,000
BTU/h
3,100~22,000
8.8
HSPF
BTU/hW
27.2
SEER
BTU/hW
16.1/15.0
EER
Clg/Htg
14~115 (-10~46)
-15~75 (-26~24)
Pt./h(l/h)
2.75 (1.3)
208-230/60/1 208-230/60/1
15
(A)
500 (850)
Air Circ.
: Hi
C.F.M. (m
/h)
3
394 (670)
Medium
324 (550)
Low
Quiet
194 (330)
Noise Level
: Hi
dB(A)
43/43
Medium
37/38
Low
32/32
Quiet
21/21
RPM Clg/Htg
780/780
48/49
dB(A)
: Cooling
2.7
(A)
Rated
Heating
3.7
: Cooling
.56
(kw)
Rated
Heating
.80
Fan Speeds Stage
4+Auto
Air Direction: Horizontal
Manual
Vertical
Auto
Air Filter
Washable
Apple Catechin Filter
Yes
Connection Method
Flare
9 (2.7)
Ft (m)
66 (20)
Ft (m)
(pre-charge: 49')
Max. Vertical Diff.
Ft (m)
49 (15)
Inch
Suc. 3/8 Dis. 1/4 Suc. 3/8 Dis. 1/4
Net Weight lbs.
(kg)
21 (9.5) 88 (40) 21 (9.5) 88 (40)
Inch
11-1/8
13-1/4*
mm
282/337*
Width
Inch
34-1/4
31-3/32
mm
870
Depth
Inch
7-1/4
11-13/32
mm
185
Refrigerant
R410A
Note: Figures are based on 230 Volts. *Height when front panel is open.
Up to 27.2 SEER
12RLS2H
15RLS2H
Heat Pump
Heat Pump
12,000
14,500
3,100~18,400
3,100~13,600
16,000
18,000
3,100~22,100
3,100~23,900
9.3
10.3
25.0
21.5
13.8/13.3
12.0/13.3
14~115 (-10~46)
14~115 (-10~46)
-15~75 (-26~24)
-15~75 (-26~24)
3.8 (1.8)
4.44 (2.1)
208-230/60/1
15
20
500 (850)
530 (900)
394 (670)
436 (740)
324 (550)
336 (570)
194 (330)
229 (390)
45/45
43/43
37/38
40/40
32/32
33/34
21/21
25/27
870/780
870/780
49/50
51/51
4.0
5.5
6.1
5.5
.87
1.21
1.20
1.35
4+Auto
4+Auto
Manual
Manual
Auto
Auto
Washable
Washable
Yes
Yes
Flare
Flare
9 (2.7)
9 (2.7)
66 (20)
66 (20)
(pre-charge: 49')
(pre-charge: 49')
49 (15)
49 (15)
Suc. 1/2 Dis. 1/4
21 (9.5) 88 (40)
11-1/8
11-1/8
24-1/2
24-1/2
24-1/2
13-1/4*
13-1/4*
620
620
620
282/337*
282/337*
34-1/4
34-1/4
31-3/32
31-3/32
790
870
790
870
790
7-1/4
11-13/32
7-1/4
11-13/32
290
290
290
185
185
R410A
R410A
19