AEG L6FBE740G Руководство пользователя - Страница 27
Просмотреть онлайн или скачать pdf Руководство пользователя для Стиральная машина AEG L6FBE740G. AEG L6FBE740G 36 страниц.
WARNING!
• Do not remove the filter
while the appliance
operates.
• Do not clean the pump if
the water in the
appliance is hot. Wait
until the water cools
down
Proceed as follows to clean the pump:
1. Open the pump cover.
1
2. Place a suitable bowl below the drain
pump access to collect the water that
flows out.
3. Squeeze the two levers and pull the
drainage duct forward to open it.
4. Let the water flow out.
2
1
1
2
5. When the bowl is full of water, close
the drainage duct back and empty
the container.
6. Repeat the steps 4 and 5 until the
water stops to flowing out.
1
7. Close the drainage duct and turn the
filter anti-clockwise to remove it.
1
8. If it is necessary, remove fluff and
objects from the filter recess.
9. Make sure that the impeller of the
pump can rotate. If it does not
rotate, contact the Authorised
Service Centre.
10. Clean the filter under the water tap.
ENGLISH
27
2
2