Fujitsu Primergy BX620 S2 Руководство по конфигурированию системы и информации о заказах - Страница 17

Просмотреть онлайн или скачать pdf Руководство по конфигурированию системы и информации о заказах для Сервер Fujitsu Primergy BX620 S2. Fujitsu Primergy BX620 S2 18 страниц.

PRIMERGY BX620 S2 / BX620 S3
BX600 S2 Blade Server System Unit
Connection between BX620 S2 / BX620 S3 and Network Blade
Please refer to the following connection patterns between BX620 S2 / BX620 S3 and Network Blade.
BX620 S2 / BX620 S3
Structure
Interface
LAN
Onboard LAN
+ LAN
1Gbit/s Ethernet I/O Module
(optional)
cannot be mounted with
2Gbit/s FC I/O Module (*)
+ Fibre Channel
2Gbit/s FC I/O Module
(optional)
cannot be mounted with
1Gbit/s Ethernet I/O Module (*)
* BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
KVM Module
KVM Module Slot
Max: 1
Notes on KVM Module (PG-KVB101)
* KVM Module (PG-KVB101), PRIMERGY BX600 Management Blade and Client PC are connected to same network.
Management Blade
Max: 2 Blades
Management
Blade Slots
Standard: 2 Blades
Port
Port 1
Port 2
Port 1
Port 2
Port 1
Port 2
PRIMERGY BX600 KVM Module
Standard: 1 Unit
KVM Module Conversion kit
PGBKVU101
KVM Module
PG-KVB101
PRIMERGY BX600
Management Blade
Network Blade
Switch Blade / GbE Pass-Thru Blade /
FC Switch Blade / FC Pass-Thru Blade
Network Blade 1
(optional : Switch Blade (PG-SW104/PGBSW1040/PG-SW105/PGBSW1050) /
GbE Pass-Thru Blade(PG-LNB101/PGBLNB1010) )
Network Blade 2
(optional : Switch Blade (PG-SW104/PGBSW1041/PG-SW105/PGBSW1051) /
GbE Pass-Thru Blade(PG-LNB101/PGBLNB1011) )
Network Blade 3
(optional : Switch Blade (PG-SW104/PGBSW1042/PG-SW105/PGBSW1052) /
GbE Pass-Thru Blade(PG-LNB101/PGBLNB1012) )
Network Blade 4
(optional : Switch Blade (PG-SW104/PGBSW1043/PG-SW105/PGBSW1053) /
GbE Pass-Thru Blade(PG-LNB101/PGBLNB1013) )
Network Blade 3
(optional : FC Switch Blade (PG-FCS102/PGBFCS102) /
FC Pass-Thru Blade (PG-FCB101/PGBFCB101) )
Network Blade 4
(optional : FC Switch Blade (PG-FCS102/PGBFCS1022) /
FC Pass-Thru Blade (PG-FCB101/PGBFCB1012) )
Twist Pair Cable
Twist Pair Cable
HUB
RS-232C Cross Cable
* for setting Management Blade
* one cable attached with BX600 S2 Blade
Server System Unit (PGUR3SC1) as standard.
Twist Pair Cable
Display/Keyboard/Mouse
Display/Keyboard/Mouse
PRIMERGY BX600
Operator Client
HUB
Supervisor Client