Fujitsu ETERNUS DX8700 S2 Руководство по конфигурации
Chapter 2
Setting Up the ETERNUS DX
2.1
Common Settings
2.1.2

Creating the Server Accessible LUN Groups (Setting the LUN Groups)

Create LUN groups for the server to access. Refer to "Connectivity Management" in "ETERNUS Web GUI User's
Guide" for details, and set the LUN groups.
Depending on the OS version, the server may not recognize the ETERNUS DX unless a LUN group is as-
signed from LUN0. In this case, assign a LUN group starting from LUN0 in ascending order.
2.1.3

Setting the Host Responses

The host response parameters for the ETERNUS DX must be set to match the way the server processes the
responses to requests from the ETERNUS DX. Setting of the host response must be done before connecting
the ETERNUS DX to the server.
Set the parameters that are described below for each OS.
Retain the default values for all of the parameters that are not described below.
When setting the access path using the ETERNUS SF Storage Cruiser, the host responses for FC host will
be set to default values. Set the host response after setting the access path using the ETERNUS SF Stor-
age Cruiser.
Since "Windows EMPD", "Linux EMPD", "Solaris EMPD", or "Others" cannot be selected after applying the
latest firmware, select "Default" for the Host Response setting.
Note that these items are displayed as the existing setting, but do not need to be changed.

Table 2.5 Host response settings

OS
Solaris (*1)
®
Windows
Linux
VMware ESX
PAN Manager
Citrix XenServer
Oracle VM Server for
x86
HP-UX
Conditions
When all of the following con-
ditions are met
The OS standard Multipath
Driver (MPxIO) is used
The Multipath Diagnostic
Program (or Enhanced Sup-
port Facility 5.1 or later) is
installed
When an MPxIO that is differ-
ent from the above is used
When the ETERNUS Multipath
Driver or the Symantec Stor-
age Foundation is used
10
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-
Copyright 2015 FUJITSU LIMITED
Host response selec-
Parameter
tion
None
Reservation Conflict Re-
sponse for Test Unit
(Create a new host re-
Ready
sponse)
Sense Data Conversion
Solaris MPxIO
Default
Default
HP-UX
Setting value
Conflict
4/*/* g 6/*/*
B/*/* g 6/*/*