Fujitsu Eternus DX90 Руководство по конфигурации - Страница 10
Просмотреть онлайн или скачать pdf Руководство по конфигурации для Хранение Fujitsu Eternus DX90. Fujitsu Eternus DX90 16 страниц. Disk storage system
Также для Fujitsu Eternus DX90: Руководство пользователя (35 страниц), Использование дополнительных продуктов (2 страниц)
Chapter 2
Setting Up the ETERNUS DX
2.1
Common Settings
Table 2.5 Host response settings
OS
Solaris (*1)
HP-UX
AIX (*2)
VIOS
®
Windows
(*3)
Linux
Conditions
When MPxIO is used and the Multi-
path Diagnostic Program or En-
hanced Support Facility 5.1 or later
is installed
When MPxIO is used for purposes
other than described above
When the ETERNUS Multipath Driver
or VxVM is used
Common (required setting)
When Integrity VM is used
Common (required setting)
When one of the following condi-
tions applies
•
ETERNUS Multipath Driver 2.0 is
used
When FJspio is used and PowerHA
•
or HACMP is used for a single path
configuration
When one of the following condi-
tions applies
The OS standard multipath driver
•
(msdsm) is used
VxVM is used
•
When one of the following condi-
tions applies
SAN Boot is configured with the
•
PRIMEQUEST 1000 series
SAN Boot is configured with the
•
PRIMEQUEST 500/400 series
When the ETERNUS Multipath Driver
is used
When MSCS is used on Windows
®
Server
2003
When one of the following condi-
tions applies
The OS standard multipath driver
•
(device mapper) is used
VxVM is used
•
SAN Boot is configured with the
•
PRIMEQUEST 1000 series
SAN Boot is configured with the
•
PRIMEQUEST 500/400 series
Conditions that are not listed above
10
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-
Copyright 2015 FUJITSU LIMITED
Parameter
Reservation Conflict Response for
Test Unit Ready
Sense Data Conversion
Reservation Conflict Response for
Test Unit Ready
Sense Data Conversion
All parameters
Host Specific Mode
Sense Data Conversion
Host Specific Mode
Reservation Conflict Response for
Test Unit Ready
Sense Data Conversion
Sense Data Conversion
All parameters
Reservation Conflict Response for
Test Unit Ready
Sense Data Conversion
All parameters
Setting value
Conflict
MPxIO Recommended
Conflict
Linux Recommended
(When not using
GRMPD)
Default value
HP-UX Mode
Linux Recommended
(When not using
GRMPD)
AIX Mode
Conflict
Windows Recommen-
ded (When not using
GR/ETERNUS MPD or
Device Driver)
Linux Recommended
(When not using
GRMPD)
Default value
Conflict
Linux Recommended
(When not using
GRMPD)
Default value
P3AM-3182-15ENZ0