Fujitsu D2932 Техническое руководство - Страница 18
Просмотреть онлайн или скачать pdf Техническое руководство для Материнская плата Fujitsu D2932. Fujitsu D2932 32 страницы. For rx330 s1
PCI bus
The following interrupt signals are used in the system depending on the
installed riser card (1 or 2) and the use of a ZCR controller:
With riser card 1:
Slot/device
VGA
LSI 1068
LAN
Slot 4
Slot 3
Slot 2
Slot 1
With riser card 2:
Slot/device
VGA
LSI 1068
LAN
Slot 4
Slot 3
Slot 2
Slot 1
If a ZCR controller has been installed in slot 2, the LSI1068-Controller is hidden
in the device list and its interrupt signal goes no longer directly to the system.
Assignment of the PCI interrupts
If you select Auto in the BIOS setup, the interrupts are assigned automatically
and no further settings are required.
18
Property
iRMC graphic
PCI-X SAS controller
BCM5715 Dual Channel
PCIe x8
PCI-X (66 MHz)
PCI-X (66 MHz) inclusive ZCR PCI-X-INTA, PCI-X-INTB, PCI-X-INTC,
PCIe x8
Property
iRMC graphic
PCI-X SAS controller
BCM5715 Dual Channel
PCIe x8
PCIe x4
PCI-X (66 MHz) inclusive ZCR PCI-X-INTA, PCI-X-INTB, PCI-X-INTC,
PCIe x8
Technical Manual
Interrupt signal
PCI-INTA
PCI-X-INTC
PCI-X-INTD, PCI-X-INTA, PCI-X-INTB,
PCI-X-INTC
PCI-X-INTD
Interrupt signal
PCI-INTA
PCI-X-INTC
PCI-X-INTD
D2440/D2932 (RX330 S1)
Features