When used as an extractor unit, the hood must be fitted with a
100mm diameter hose.
If the fumes must be forced out through the wall, you must obtain
a MKZ sizable wall exhaust pipe (with external exhaust and air
intake), E-Nr.- 610 899 004 (Ø 120 mm) which is one of our
optional parts.
When installing the hood, make sure you respect the follow-
ing minimum distance from the top edge of the cooking hob/
ring surfaces:
electric cookers
gas cookers
coal and oil cookers
Where flexible ducting is fitted the length should be no more
than:
— 3 metres with one 90° bend
— 2 metres with two 90° bends.
Bends of more than 90° will reduce the efficiency of the hood
and reduce the air flow.

General details

The hood is supplied as a ducted version, but may also be used
in recirculation mode by inserting a charcoal filter (Special
accessories).
The air is ducted out through a pipe which is connected to the
outlet hole A (fig. 1) by means of a coupling flange B.
To connect the hood to a wall box, you use hoses and wall boxes
as offered on the AEG price list as optional extras.
1
650 mm
700 mm
900 mm min.
B
A
Extractor
version
7