Kohler 1.1746.005 Руководство по установке и эксплуатации - Страница 22
Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Сантехника Kohler 1.1746.005. Kohler 1.1746.005 29 страниц.
Start/Stop
Symptom
Light is
ON or OFF
No
change in
temperature
between
Low / Eco /
High setting.
Water will
OFF
not turn off.
Shower fails
to produce
hot water
when set on
Eco / High
setting.
Water leaks
from the
bottom of
the case
and there
is no flow
OFF
from the
showerhead.
1494247-W2-A
Power
Control
Position
ON
ANY
ANY
ECO/
ON
HIGH
ANY
Possible Cause
Microswitch failure.
Insufficient mains water
pressure.
Possible failure of flow
valve, microswitch or
heater tank.
Flow valve, solenoid or
Start / Stop switch faulty.
Insufficient water supply.
Possible failure of the
microswitch or thermal
switch.
Hose kinked or blocked.
The PRV has been
triggered, (the shower
has a pressure relief
valve assembly to reduce
damage if the outlet is
blocked or the shower is
frozen). When the relief
valve operates a small
rubber ball is ejected.
22
Possible Remedy
Replace microswitch.
Contact local water
company.
Use a suitable device to
check the continuity of
the microswitch or heater
tank and replace parts as
necessary.
Replace as necessary.
Contact local water
company.
Use a suitable device to
check the continuity of
the microswitch or heater
tank and replace parts as
necessary.
Check hose and replace if
necessary.
Replace heater tank.