Troubleshooting (cont.)
Symptoms
5.
Blower motor starts, some
but not all airjets are
working.
Blower motor runs but no
6.
air bubbles are observed.
7.
Blower motor operates,
air bubbles are observed,
but speed feature does
not work.
8.
Blower motor does not
turn off when the On/Off
button is pressed.
9.
Purge mode does not
work.
10. Bath does not purge
automatically.
1198326-2-A
Probable Causes
A. Blower motor speed is too low.
B. Blower motor inlet is blocked.
C. Blower motor does not work.
D. Blower motor discharge is
blocked.
E. Check valve does not work.
F.
Airjets are clogged.
A. Blower motor inlet is blocked.
B. Airjets are clogged.
C. Check valve does not work.
D. Blower motor does not work.
A. Blower motor inlet is blocked.
B. Loose, disconnected, or
damaged wiring harness.
C. User keypad does not work.
D. Blower motor does not work.
A. User keypad does not work.
B. Loose, disconnected, or
damaged wiring harness.
C. Control does not work.
A. User keypad does not work.
B. Control does not work.
A. Blower does not work.
14
Recommended Action
A. Increase speed.
B. Clean blower motor inlet.
C. Replace the blower motor.
D. Clear blockage.
E. Replace the check valve.
F.
Use a small between-the-teeth
dental brush and white vinegar.
Dip the brush in the vinegar, brush
the hole, rinse the brush in clean
water, and then use the wet rinsed
brush to rinse the hole.
A. Clean blower motor inlet.
B. Use a small between-the-teeth
dental brush and white vinegar.
Dip the brush in the vinegar, brush
the hole, rinse the brush in clean
water, and then use the wet rinsed
brush to rinse the hole.
C. Replace the check valve.
D. Replace the blower motor.
A. Clean blower motor inlet.
B. Check wiring for proper
connections. Replace the wiring
harness if necessary.
C. Replace the user keypad.
D. Replace the blower motor.
A. Replace the user keypad.
B. Check wiring for proper
connections. Replace the wiring
harness if necessary.
C. Replace the control.
A. Replace the user keypad.
B. Replace the control.
A. Replace the blower.
Kohler Co.