Kohler ADAIR K-75925T Руководство по установке - Страница 9

Просмотреть онлайн или скачать pdf Руководство по установке для Туалеты Kohler ADAIR K-75925T. Kohler ADAIR K-75925T 10 страниц. 4.0l exposed class five one-piece toilet
Также для Kohler ADAIR K-75925T: Руководство по установке (8 страниц)

Kohler ADAIR K-75925T Руководство по установке
SYMPTOMS
1. Poor Flush
2. No Flush
3. The fill valve turns on/off by itself
without the toilet being flushed, or it
runs allowing water to enter the tank.
4. Tank takes excessive time to fill.
5. There is excessive noise when the
tank is filling.
IMPORTANT: Use only genuine Kohler parts as shown to avoid property damage.
1.
2.
3.
/
4.
5.
1285052-T01-A
CORRECTIVE ACTION
A. Adjust the tank water level to match the waterline.
B. Fully open the water supply shut-off valve.
C. Clear obstructions from the trapway, jet, or bowl rim holes.
D. Clear obstructions from the waste line.
A. Reconnect the chain to the trip lever or flush valve.
B. Adjust the chain assembly to remove excessive slack.
A. Adjust the chain for proper slack so the seal is not held off the flush valve seat.
B. Clean or replace the seal if it is worn, dirty, or misaligned with the flush valve seat, or
if the flush valve seat is damaged. Replace the flush valve seal or flush valve.
C. Clean the fill valve seat/seat washer of debris, or replace the piston/seat washer
assembly.
D. Remove the tank and tighten the flush valve nut if flush valve gasket is leaking. Do
not overtighten. If leakage continues, replace the gasket.
E. Adjust the tank water level if it is too high.
A. Fully open the water supply shut-off valve.
B. Clean the valve inlet, valve head, or supply line. Flush the lines.
A. Partially close the water supply shut-off valve if the water pressure to the toilet is too
high. Check the toilet performance following any such adjustment.
B. Remove dirt or obstructions from the valve head. Flush the lines.
A.
B.
C.
D.
A.
B.
A.
B.
C.
D.
E.
A.
B.
A.
B.
-9-
/