Carefully align and lower the bowl. Apply weight to the bowl
rim to let the outlet insert into plastic trap. See Fig.#12
Carefully thread the screws into the brackets, until toilet is
secure. Alternately tighten left and right sides to prevent
pulling the toilet off center. Install cap to cover screw. See
Fig.#13
Do not overtighten.
Outlet
Plastic Trap
Apply caulk around base.
TO CONNECT WATER
SUPPLY
* Flexible hose are recommended to
connect the supply line to the fill valve.
If you use a rigid connection (not
provided), take care not to apply side
forces to the bottom of the fill valve. Be
sure the rigid connection must be fit
with supply line completely to prevent
damage shank by forced connection.
IMPORTANT:
Before turning on the supply valve for the first
time, follow the steps below to clear sand, debris and rust
from the system:
Make sure water supply is off. Remove valve END by
rotating it 1/8 turn counterclockwise.
While holding a container over the uncapped VALVE to
prevent splashing, turn water supply on and off a few times.
Leave water supply off.
Replace END by engaging lugs and rotating 1/8 turn
clockwise.
Make certain the top is turned to the locked
position. Valve may not turn on if top is not fully in the
locked position.
Turn on water supply. Check that water level is at the marked
water line.
1392769-T01-C
Fig.#12
12
Supply Shank*
Bushing
Screw
Cap
Fig.#14
14
Supply Shut-Off Valve
Fig.#15
15
-5-
12
13
Fig.#13
13
)
1/8