One-Year Warranty (cont.)
AV. CARLOS PACHECO NO. 7200
CHIHUAHUA, CHIH., MEXICO C.P. 31060
TEL: 52 (14) 29-11-11
Troubleshooting Guide
Troubleshooting Tips
NOTE: This troubleshooting guide is for general aid only. For
warranty service, contact your dealer or wholesale distributor.

Troubleshooting Table

Symptoms
1.
Poor flush.
2.
No flush.
Bowl water
3.
continues to flow
or tank fill water
will not shut off.
1054184-5-A
Recommended Action
A. Clean under the bowl rim.
B. Plunge the bowl, auger the trap, and auger
the drain to clear any blockage.
C. Adjust the gap between the actuator and
plunger arm to approximately 1/8" (3
mm).
D. Fully open the supply stop.
E. Clean the screen with a medium to hard
bristle brush. Replace the screen if
necessary. (Phone 1-800-533-3450 for
assistance.)
Clean or replace the flow regulator.
F.
G. Refer to installer/dealer for assistance.
A. Fully open the water supply stop.
B. Tighten the nut (turn counterclockwise to
tighten).
C. Hook the plunger arm over the trip arm.
D. Clean the screen. (Phone 1-800-533-3450
for assistance.) Replace the screen if
necessary
E. Clean or replace the flow regulator.
F.
Replace inlet components. (Phone
1-800-533-3450 for assistance.)
A. Adjust the gap between the actuator and
plunger arm to approximately 1/8" (3
mm).