NXT STAGER DIMENSIONS
11.13 [282.7]
8.91 [226.3]
Optional
Solenoid
10.50 [266.6]
5.25 [133.4]
1.41 [35.8]
(6X) 1/8" NPT PORT 60 APART
*
ø
0.733 [18.62 mm]
4 places
*
ø
0.88
[22.4 mm]
2.45 [62.2]
2.75 [69.9] 2.75 [69.9]
2.06 [52.3]
48ES STAGER
6.42 [163.1]
1.25 [31.7]
11.13 [282.7]
.32 [8.1]
1/8" NPT Filtered Inlet
(8X) 1/8" NPT - 45 APART
*
ø
0.733 [18.62 mm]
4 places
*
ø
0.88
[22.4 mm]
51ES STAGER
*
NOTE: Drill as required. These holes
will only be drilled at factory if
required.
Figure 1
NXT Stager Controller AU11
1/8" NPT Drain
3.50 [88.9]
2.72 [69]
2.00 [50.8]
1/8" NPT Filtered Inlet
4.00 [101.6]
6.00 [152.4]
(4X) .19 [4.8]
(4X) R.16 [4]
1/8" NPT Drain
1.75 [44.4]
1/8" NPT Drain
SYSTEM SPECIFICATIONS 48 AND 51
NXT SERIES
Generic Meter Guidelines
• Open collector output
• Pulse rate generated must not exceed 100 pulses per
second (100 Hz), or 6,000 pulses per minute
• Support for meter outputs in the range of 1-255 gallons
(25.5 m
) for every 1-255 pulses
3
Example: 35 gallons/100 pulses
(=3.5 gallons/10 pulses, = 0.35 gallons/1 pulse)
• Meter must operate at 5 VDC
Electrical Rating
• 115 VAC ±20% input, 24 VAC output w/50 VA (maintain
input voltage in this range)
• 230 VAC ±20% input, 24 VAC output w/50 VA (maintain
input voltage in this range)
• Max Rated Power 15W
Humidity
• 95% RH, non-condensing
Temperature
• Maximum control fluid temperature 140°F (60°C)
• Operate where ambient temperatures are above 32°F
and below 110°F
Pressure
• Maximum control fluid pressure 125 psi (8.5 bar)
• Control fluid can be either water or air and must be equal