Safety instructions and references on the operation:
Safety instructions and references on the operation:
Safety instructions and references on the operation:
Safety instructions and references on the operation:
The black varnish must not be damaged as this might lead to erroneous measurements
and removes any warranties and claims!
The light emitting diode at the tip of the sensor may corrode when in contact with water
and may loose the functionality. This normal chemical reaction does not constitute an
operation error and therefore is not liable for warranty claims.
After a long usage sedimentation may occur on the sensor which could disturb the correct
measurements. In this case the sensor may be carefully cleaned with a soft cloth and clear
running water.
To recognize measurement errors at an early stage, e.g. by staining or damages to the
sensor, the correct functionality of the sensor must be monitored regularly. We accept no
responsability for consequentional damages that occur through incorrect usage!
Installation instructions:
Installation instructions:
Installation instructions:
Installation instructions:
Hand-screw the tubemeter™ in a vacant opening of the aquatube or in the lid of the
aquainlet (fitting lid with G1/8-thread is separately available as an accessory). The narrow
part of the circuit board with the gold-plated measurement surfaces is supposed to be
submerged in the cooling liquid, the connector side must stay dry. To use the maximum
measuring area the sensor should be istalled perpendicular to the water surface. Only
hand-screw the sensor, do not use any tools to fasten it!
Connect the sensor to an available USB-connector of your mainboard (cable included in
delivery) or to an available aquabus-connector (cable not included in delivery) e.g. on the
aquaero™ (not included in delivery).
Device settings:
Device settings:
Device settings:
Device settings:
No settings may be made to the sensor directly. The sensor automatically detects wether it
is connected via USB or the aquabus and configures itself accordingly. All settings are
made with the pc-Software „aquasuite", where the measurements may be interpreted.
Updated versions of the software may be found at
„support" -> „download" area.