IMPORTANT SAFETY INSTRUCTION
When using electrical appliances, basic safety precautions should be followed to reduce the risk
of fire, electric shock and injury to persons or property. Read all instructions before using any
appliance.
• Keep combustible material such as furniture, bedding, pillows, clothes and/or papers away from
the unit.
• Do not operate this, or any other appliance, with a damaged power cable.
• No other appliance should be connected into the same power supply.
• Do not run the power cable over carpeting or other heat insulators.
• Keep the power cable away from high traffic areas.
• Do not submerge the power cable in water.
• We do not recommend the use of joint cables as they may overheat and increase the risk of fire.
• Exercise caution and use reasonable supervision when the appliance is used by or near children.
• Keep a minimum distance on each air-louvre side free.
• Do not use this product to dispense anything other than water.
• Do not use this product to dispense anything other than water.
• This appliance must be installed on an even and flat surface or wall.
• If the power cable or terminal is damaged, one of its service agents or a similarly qualified person
must replace it to avoid hazard.
• Switch off the main power source before servicing the appliance.
• Warranty will be voided if installation is not carried out as detailed in this instruction manual.
• The compressor motor is equipped with an automatic reset protector which will disconnect the
motor from the
line in case of an overload.
IMPORTANT INFORMATION ABOUT GROUNDING
•
To provide additional protection from the risk of shock, this unit must always be connected to
a residual-current device (RCD) or a breaker. Use of joint cable should be avoid.
•
This appliance must be grounded. Improper use of the grounding plug can result in a risk of
electric shock, causing serious injury and possibly death.
•
This appliance is equipped with the power terminal or power cord. A ground connection
must be connected into a properly grounded, polarised outlet.
•
Consult a qualified electrician if the grounding instructions are not completely understood, or
if doubt exists as to whether the appliance is properly grounded.
•
Do not under any circumstances cut or remove the third (ground) prong from the power cord
plug (if provided). Do not use an adapter plug with this appliance.
INSPECTION
Inspect the cartons and various components for evidence of rough handling and concealed
damage. Damage claims should be filed with the carrier.
Your Partner in Cool.
4
INSTALLATION
The installation must be in accordance with AS/NZS 3500.1 and AS/NZS 3500.2, as well as the
instructions below. Pipe jointing and installation is a trade skill and Aqua Cooler recommended
this process is performed by qualified personnel only.
The water cooler contains the refrigeration system and is always mounted on the right side. This
unit can be configured with the water cooler high or low. Refer to proper roughing in drawing for
location of plumbing and electrical service. Filter units have additional instructions on a label
inside fountain side access panel. Read these before installing unit. This drinking water cooler is
designed to be operated at a water supply line pressure of up to 100 psi (690 kPa). A pressure
regulator must be installed in front of the unit's water inlet if the water pressure (including any
possible pressure spikes) could exceed 100 psi (690 kPa).
FLUSH BUILDING WATER SUPPLY BEFORE INSTALLING UNIT.
Install wall hangers as shown on the desired roughing in drawing. Wall hangers are shipped
fastened to the backs of each unit.
To configure this cooler for right side high or right side low installation, refer to details below.
Bottom screws of the appropriate side panel may be temporarily removed to install patch plate.
Assemble drains as shown below, matching the position of the gaskets to the contour of the
cooler tops.
Mount the water cooler on the right hanger.
Mount water fountain on left side hanger while routing "Water In" tube through access hole to
stop valve as required. Remove cap from "Drain/Remote Cold Water" connection and insert
"Water In" tube.
All provided waste drain parts for field installation are packed in the water fountain. Assemble
drain per appropriate roughing in drawing. The short leg of the crossover piece will be on the
water cooler side. When unit has an internal waste trap, it should be wrapped with insulating
tape to prevent sweating. Use of 1-3/4" knockout for a waste line is not recommended because
of potential conflict with ADA* toe space requirements. Check with your local building code
inspector for approval.
Install a shut off valve in water supply line. An in-line strainer is furnished in "Water Supply" tube.
Connect "Water Supply" tube to shut off valve. This connection should not be a solder joint or
flare connection to allow access to the strainer service. To ease removal of the strainer, a sheet
metal screw may be lightly threaded into the open end.
Rotate fan blade by hand to see that it is free of obstructions.
Check available power supply against water cooler data plate to assure correct electrical service.
This drinking water cooler is intended to be connected to a 20A minimum ground fault circuit
interrupting (GFCI) device to meet UL requirements. Plug power supply cord into wall outlet. The
rear most 1-3/8 diameter knockout in frame bottom is for an externally located electrical supply.
Make sure knockout hole edge is smooth and free of any burrs. Use of Heyco bushing #2184 in
knocked out hole is recommended to prevent damage to service cord and to close up excess
opening around cord. Route cord so it does not interfere with ADA* space requirements.
5