Aqua Cooler AC-MWSM8EBFY-ASM Руководство по использованию и уходу - Страница 3
Просмотреть онлайн или скачать pdf Руководство по использованию и уходу для Охладитель Aqua Cooler AC-MWSM8EBFY-ASM. Aqua Cooler AC-MWSM8EBFY-ASM 7 страниц. Semi-recessed bottle filler
IMPORTANT SAFETY INSTRUCTION
When using electrical appliances, basic safety precautions should be followed to reduce the risk
of fire, electric shock and injury to persons or property. Read all instructions before using any
appliance.
• Keep combustible material such as furniture, bedding, pillows, clothes and/or papers away from
the unit.
• Do not operate this, or any other appliance, with a damaged power cable.
• No other appliance should be connected into the same power supply.
• Do not run the power cable over carpeting or other heat insulators.
• Keep the power cable away from high traffic areas.
• Do not submerge the power cable in water.
• We do not recommend the use of joint cables as they may overheat and increase the risk of fire.
• Exercise caution and use reasonable supervision when the appliance is used by or near children.
• Keep a minimum distance on each air-louvre side free.
• Do not use this product to dispense anything other than water.
• Do not use this product to dispense anything other than water.
• This appliance must be installed on an even and flat surface or wall.
• If the power cable or terminal is damaged, one of its service agents or a similarly qualified person
must replace it to avoid hazard.
• Switch off the main power source before servicing the appliance.
• Warranty will be voided if installation is not carried out as detailed in this instruction manual.
• The compressor motor is equipped with an automatic reset protector which will disconnect the
motor from the
line in case of an overload.
IMPORTANT INFORMATION ABOUT GROUNDING
•
To provide additional protection from the risk of shock, this unit must always be connected to
a residual-current device (RCD) or a breaker. Use of joint cable should be avoid.
•
This appliance must be grounded. Improper use of the grounding plug can result in a risk of
electric shock, causing serious injury and possibly death.
•
This appliance is equipped with the power terminal or power cord. A ground connection
must be connected into a properly grounded, polarised outlet.
•
Consult a qualified electrician if the grounding instructions are not completely understood, or
if doubt exists as to whether the appliance is properly grounded.
•
Do not under any circumstances cut or remove the third (ground) prong from the power cord
plug (if provided). Do not use an adapter plug with this appliance.
INSPECTION
Inspect the cartons and various components for evidence of rough handling and concealed
damage. Damage claims should be filed with the carrier.
Your Partner in Cool.
4
INSTALLATION
The installation must be in accordance with AS/NZS 3500.1 and AS/NZS 3500.2, as well as the
instructions below. Pipe jointing and installation is a trade skill and Aqua Cooler recommended
this process is performed by qualified personnel only.
Plumbing rough-in and wall opening should be prepared as shown on roughing-in drawing.
nsert frame assembly into wall opening and secure to studs. NOTE: FRONT FLANGE OF
FRAME(S) MUST BE FLUSH WITH THE FINISHED WALL SURFACE.
Install drain receptor to frame with screws provided.
A 2X4 junction box is provided for the installation of a 115 volt receptacle. The bottle filler is
provided with a power cord with a grounded NEMA 15 plug. It is recommended that flexible
conduit be used to supply power to the junction box and chiller if used. Check the electric current
available. Type and voltage must be the same as listed on the unit data plate.
Refer to the appropriate connection diagram for water and drain connections. Check for leaks.
The lower panel can be secured with the provided key locks or screws. The M8SBF features one
lockable and one non lockable lower panel, these are interchangeable.
MODELS WITH CHILLER
Attach cradle mounting angles to unit mounting cradle with 4 screws provided. Slide unit
mounting cradle into frame and secure in place with 4 screws, provided. (Cradle is used only when
cooling unit is to be installed.) NOTE: BOTTOM FLANGE ON CRADLE IS TO
BE BEHIND FRAME FRONT FLANGE.
Slide cooling unit onto cradle.
INSTALL MOUNTING FRAME
A - Install frame per rough in drawing
B - Install drain assembly
C - Install snap bushings
5