Aqua Creek Products F-802SC2 Руководство - Страница 3

Просмотреть онлайн или скачать pdf Руководство для Подъемные системы Aqua Creek Products F-802SC2. Aqua Creek Products F-802SC2 16 страниц. Lift graph
Также для Aqua Creek Products F-802SC2: Руководство (2 страниц), Краткое руководство по эксплуатации (4 страниц)

ADA REQUIREMENTS
The Scout 2 Lift is completely ADA Compliant when installed correctly.
The installation must meet the following requirements:
Clear deck space dimensions (see FIGURE 1)
Install lift a minimum of 19 inches from the pool edge
(For curved pool walls contact Aqua Creek for placement)
Deck slope no greater than 1:48
The seat must be submerged at least 18 inches into the water. The lift
should be installed at a location with 42-48 inches of depth (deck to pool fl oor)
NOTE: Other requirements may be necessary based on local code requirements. The anchor system
should be bonded according to NEC Section 680 and/or local code requirements.
Copyright © 2017 Aqua Creek Products All Rights Reserved
Installation: ADA Guidelines
(For Commercial Applications)
ADA
CLEAR
DECK
SPACE
18"
19" (MIN)
35" (MAX)
:
71"
62"
48"
12"
DECK
WATER
POOL WALL
FIGURE 1
3
Revised 5/9/17