Aqua Euro USA 1 HP Руководство по эксплуатации - Страница 3
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Охладитель Aqua Euro USA 1 HP. Aqua Euro USA 1 HP 7 страниц.
SET UP
1.
The chiller must be operated with a water pump or filtration system
2.
Connect external flexible hoses to the inlet and outlet. Position the rubber gasket and seal ring provided around
the flexible hoses, insert the hoses into the chiller and screw tight to secure in place
3.
Install chiller in dedicated location that has plenty of air flow.
Inside an open cabinet
4.
Quantity of circulating water must be in compliance with technical data or cooling elements will be adversely
affected.
5.
Head of circulating pump should not exceed 19' – leakage and other damage may result.
Before turning chiller on:
6.
Chiller water inlet must be connected to a water pump with a filter or external filter to ensure the water intake is
pure. All saltwater must be filtered before entering the chiller, or the evaporator will get dirty and this will affect
the performance of the chiller.
7.
Once all connections are made, circulate water through chiller for 30 minutes before turning the unit on. Check
all connections for water leakage and/or obstruction. Check pump is operational and unblocked.
8.
Do not run chiller without water.
PROGRAMMING
1.
Plug the chiller into a dedicated GFCI (ground fault circuit interrupter) protected 115V (60Hz) electrical outlet.
The power button will come on and the LCD operating plate will display the current water temperature.
2.
Press the "SET" button to adjust to the desired temperature.
Press ▲ to increase the temperature and ▼ to decrease temperature.
3.
The chiller begins to operate at a temperature that is 2 ˚F below the actual water temperature. After
4.
approximately 2-3 minutes of warm-up (a delayed-starting state), the chiller will begin normal operation.
5.
The "green" button will illuminate when the chiller is in operation.
6.
Chiller stops temporarily after the desired "set" temperature is reached. If the water becomes higher than the
"set" temperature, due to the influences of the environment, the chiller enters the delayed-starting state and then
re-starts. This allows the chiller to maintain the "set" water temperature.
Under an open back cabinet
Under or side of aquarium
3