To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip-
ment should be performed by qualified service personnel. The unit should be unplugged when servicing,
except when electrical tests are required.
Problem
Control Display is blank (power is on
but indicator light is off).
Control Display is blank (power is on
and indicator light is on).
Unit does not heat up (Control
Display is on).
The unit's main electrical panel
circuit breaker trips.
Water leaking inside electrical
housing.
"ERR" appears in the Control
Display.
P/N 1010456 Rev. C 08/12

TROUBLESHOOTING

WARNING
Possible Cause
The power cord is not correctly
plugged in.
The power cord and/or electrical
plug is damaged.
The main electrical panel circuit
breaker is off or has been tripped.
Switch is inoperable.
Control Board is inoperable
Transformer is inoperable.
Loose, burnt, or broken wires in
circuit.
Hi-Limit Thermostat is tripped or
inoperable.
Solid State Relay is inoperable.
Thermocouple is inoperable.
Control Board is inoperable.
Steam Generator is inoperable.
Loose, burnt, or broken wires in
circuit.
Damaged receptacle, plug, or cord;
a loose connection; or an internal
component failure.
Pinhole leak in rubber hoses.
Loose or damaged water line tubes
and/or fittings inside electrical
housing.
Programming and/or SHO and
H2O values were adjusted/changed
improperly.
13
MIRACLE STEAMER
Corrective Action
Plug the power cord into the appro-
priate outlet.
Inspect electrical wire, plug, and
receptacle.
Reset circuit breaker. Contact your
maintenance person or Authorized
Service Agency if it trips again.
Contact your maintenance person or
Authorized Service Agency for
service.
Contact your maintenance person or
Authorized Service Agency for
service.
Reset the Hi-Limit Thermostat
according to the Operations sec-
tion of this manual. If the Hi-Limit
Thermostat requires continuous
resetting, contact your Authorized
Service Agency for service.
Turn the unit off, allow it to cool to
room temperature, and then restart.
Contact your maintenance person
or Authorized Service Agency if the
condition repeats.
Replace hoses.
Tighten or replace tubes and/or
fittings.
Reset the Control Board as
described in the Programming sec-
tion of this manual. See Fault Codes.
A.J. Antunes & Co.