Aqua Flo AQUV AQUV-20R22 Руководство пользователя - Страница 9

Просмотреть онлайн или скачать pdf Руководство пользователя для Системы фильтрации воды Aqua Flo AQUV AQUV-20R22. Aqua Flo AQUV AQUV-20R22 16 страниц. Ultraviolet disinfection system

Spring
Spring
Spring
8. From the top of the gland nut, drop the lamp spring into the quartz dome.
9. Holding the top 4-pin end of the lamp, carefully slide the lamp into the
quartz dome and attach the lamp pins to the lamp connector. The lamp
connector fits over the pins in only one orientation Fig. 6D.
10. Slide the lamp connector cover over the gland nut and tighten the screw
on it Fig. 6E. Check tightening details, the screw allows
the cord to come through the plastic making it easy to hook up lamp, then white plastic part has a little screw to secure it to the gland nut.
11. Remove the nut from the ground stud at the top of the unit. Next place the ground wire (green wire with yellow stripes) over the stud and
tighten the nut.
12. Connect the ballast power cable to the AC supply (with surge protector). The green lamp-on LED will light up and the display will show "365".
This number indicates the number of days left until lamp life expires and must be replaced. Follow Step (E) before consuming water.
YOUR AQUA FLO AQUV UV DISINFECTION SYSTEM IS NOW READY FOR SERVICE.
Fig.6C
Lamp
Lamp
Lamp
Fig.6D
WARNING
Installing lamp without the spring in place can cause
breakage of quartz dome.
Fig.6E
9