AQUA FORTE O-Plus 3500 Краткое руководство по эксплуатации - Страница 2

Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Водяной насос AQUA FORTE O-Plus 3500. AQUA FORTE O-Plus 3500 9 страниц.

REMARK:
For outdoor use. The pump is to be supplied through a residual current device (RCD)
with a rated residual operating current not exceeding 30mA.
For all the models the maximum operation depth is 1,5m.
WARNING:
• Do not connect to any voltage other than that shown on the rating label of the pump.
• Do not pump flammable liquids. The appliance is only intended to be used in ponds/
aquarium.
• The maximum operation depth is 1,5m.
• Do not use with water above 35 .
• The supply cord cannot be replaced. If the cord is damaged the appliance should be
scrapped.
• The pump is not intended for use by young children or infirm persons without super-
vision.
• To protect against the risk of electrical shock, do not immerse the plug in water or
other liquid.
• This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they
do not play with the appliance.
CAUTION!!:
Always disconnect from electrical outlet before cleaning, maintenance and handling the
pump. Don't operate without water.
Do not lift the pump by holding the power cord.
Do not use the pump in liquids having a temperature exceeding 35°C.
Use the pump only in freshwater.
Please use the pump only when it is completely submerged in water.
Do not use the pump in swimming pools!!

INSTALLATION:

The pump is suited for both wet and dry applications. In a dry setup the pump must
be under water level as it is not self-priming. For dry setup the external strainer house
must be removed for the connection of the pipe fittings. Use without water (dry run-
ning) will result in irreparable damage. Under water, the pump must take in as clear as
possible water. Never place
the pump in a muddy area or on sandy pond bottoms. Put the pump on a small pedes-
tal (e.g. a stone). Ignoring these instructions can cause
blockage of the strainer house around the pump. Heavily polluted water will cause
problems for the rotor to run smooth and the pump
performance will decrease. In a worst case scenario the rotor will totally Block and the
pump will burn out. Complete blockage of the pump
strainer house will prevent motor cooling which can cause burn outs.
PERFORMANCE:
A clogged or dirty intake screen will greatly reduce performance.
If the pump is used on a dirty surface, raise it slightly to reduce the amount of debris
contacting the intake. If less flow is desired, adjust the regulator on the sealing cover to
restrict the flow.
Do not let the pump run when not submerged in water. That may damage the pump.
Always submerge the pump first, and then plug in the electrical outlet. At the begin-
ning, it probably can't pump water, because there is air in the pump and the tube. Don't
worry about it. Please pull out and insert electrical outlet several times, it will work
normally.
Automatic shut off if no water for 5 minutes (for 3500-10000), automatic shut off if no
water for 2 minutes (for 13000-30000). Pull the plug out, and re-insert to resume work.

MAINTENANCE:

Unplug before cleaning. To clean the pump, remove the back cover, sealing cover and
the impeller. Use a small brush or stream of water to remove any debris.
CAUTION!!:
The pump shaft cannot be removed!
If the pump fails to operate, check the following:
• Check the outlet and try another outlet to ensure the pump is getting electrical power.
• NOTE: Always disconnect from electrical outlet before handling the pump.
• Check the pump outlet and tubing for kinks and obstructions. Algae may block them,
please flush out the algae with a garden hose.
• Check the inlet to ensure it is not clogged with debris.
• Remove the pump inlet to access the impeller area. Turn the rotor to ensure it is not
broken or jammed.
• Monthly maintenance will prolong your pump's life.
• NOTE: Ensure that the electrical cord loops below the electrical outlet to form a "Drip
Loop". This will prevent water from running down the cord into the electrical outlet.
• When you find calcium/timescale deposits inside the motor house this implicates that
the pumps becomes too warm during use! Calcium/lime scale expands above tempera-
tures of 55°C. With sufficient flow the pump is water cooled and cannot reach these
temperatures. If, however, the head pressure is too big (too small pipe system, maxi-
mum pump head too big, etc) the flow will be reduced which causes insufficient cooling
and by this, calcium deposits. In a worst case scenario the calcium/timescale layer will
get so thick that it blocks the rotor and the motor will burn out. DAMAGE CAUSED
BY CALCIUM/LIME SCALE IS NOT COVERED BY WARRANTY! You can remove
calcium/lime scale deposits with commercial de-scaling products or vinegar
DISPOSAL:
Do not dispose this product as unsorted municipal waste. Collection
of such waste separately for special treatment is necessary.
AquaForte is a trademark of Sibo BV, Doornhoek 3950, 5465TC, Veghel, Nederland
Email:[email protected] Website: www.aqua-forte.nl