Aqua Invent AH-18 Duplex Установка и ввод в эксплуатацию - Страница 6
Просмотреть онлайн или скачать pdf Установка и ввод в эксплуатацию для Диспенсер для воды Aqua Invent AH-18 Duplex. Aqua Invent AH-18 Duplex 8 страниц. Twin-tank water softener
2. Press and hold both the "Set up" and "Set down" (
3. Set the softening capacity (treated water capacity), that is calculated above
by using
4. Press the
or
5. Press the
4.0 START UP
1. Press the
regeneration step 1 (Backwash). Open partly for incoming water and let the water
slowly enter the filter in order to purge out air from the tank. Important: If opened
too rapidly or too much for the water media may be lost.
When all trapped air has been purged out and the drain water flows steadily, open
a little bit more for water and let the water flow to drain for two minutes.
2. Press the
2 (Brine draw / slow Rinse). Wait until the motor stops.
3. Press the
3 (Rapid Rinse) and let the water flow to drain for 3 minutes.
4. Press the
4 (Brine tank Refill). Let the water flow into the brine tank for 5 minutes.
5. Press the
(Running position).
6. Repeat previous step 1 and 2 in order to start up the other tank.
7. Press the
3 (Rapid Rinse). Open fully for incoming water and let the valve automatically
advance further through remaining steps until it reaches Service position.
8. Fill salt into the brine tank until the brine tank is filled to ¾.
9. The start up is now finished; the softener now can be left to run automatically.
Make sure that the by-pass valve is in position for delivering softened
-
water.
Aqua Invent AB – AH-18 Duplex – 2019-10
or
buttons.
"Extra Reg. Button", and the display shall show "A Off". If not, us
buttons to display "A Off".
"Extra Reg. Button" to exit the program.
"Extra Reg. Button" for 5 seconds to advance the valve to
"Extra Reg. Button" once to advance the valve to regeneration step
"Extra Reg. Button" once to advance the valve to regeneration step
"Extra Reg. Button" once to advance the valve to regeneration step
"Extra Reg. Button" once to advance the valve to Service position
"Extra Reg. Button" once to advance the valve to regeneration step
) buttons for 5 seconds.
1550