Quick Install for your Aqua Logic Delta Star chiller
Unpack your Delta Star Chiller:
Carefully remove the Chiller from the box by reaching underneath the Chiller and lifting it
by its base. NEVER lift the Chiller by its cover to avoid personal injury or damage to the
Chiller (See illustration).
Use a Phillips head screwdriver to remove the two screws on opposite ends of the cover.
Place your Aqua Logic water Chiller:
Place the water Chiller on a sturdy flat surface.
Make sure that the unit is resting on its base to avoid damage.
If you place the Chiller in a cabinet, allow at least ½" of space between the Chiller and the
walls of the cabinet to avoid vibration and noise.

Delta Star Plumbing:

Your Aqua Logic flow-through Chiller requires an external water pump (not supplied) for
proper operation.
The Chiller should be the last piece of equipment in the plumbing before the water is
returned to the tank or sump (after pump and filters).
Use male-pipe-thread (MPT) fittings of the diameter below to connect your Chiller to your
system. Use the same or larger diameter pipe or hose for your plumbing for best water
flow.
We suggest installing unions and ball valves (not included) on the inlet and outlet of the
Chiller for easier installation and removal of the Chiller from the system for maintenance
or repair (if necessary).
Be sure that the water flow through your Aqua Logic Chiller goes into the water inlet
(bottom) and out the top to prevent potential damage (see illustration).
If you use flexible hose to plumb your system or connect your Chiller, make sure that the
hose is not kinked to prevent restricted flow and potential damage to your Chiller.
Avoid elbows in your plumbing to minimize flow loss through your system.
For most efficient operation, we recommend the minimum and maximum flow rates listed
in the specifications sheet for each model.
Do NOT operate the Chiller without adequate water flow.

Electrical Hookup:

We suggest using a dedicated power circuit for best operation and longest life of the Chiller. The circuit must be rated to handle the maximum load
of the Chiller.
We highly recommend that you use a ground-fault interrupter (GFI) to avoid electrical shock. You can obtain an inline GFI from Aqua Logic, a local
hardware store if the outlet in the wall does not have a GFI installed.
Avoid using an extension cord on your Chiller.
Temperature controller installation:
Follow the instructions included with the controller to install it.
o
Install the sensor for the controller "upstream" (ahead) of Chiller.
o
Plug the Chiller into the controller.
o
Plug the controller into the wall outlet.
o
Program or adjust the controller to your desired temperature. (see Chiller Controller Programming)
o
Your Aqua Logic chiller is now installed and ready for operation!