Installing the Manual Override

1. If the manual override was removed from the diaphragm cover, apply a bead of non-hardening
sealant such as Loctite Permatex Form-A-Gasket #2 to the mating surfaces of the manual
override housing and diaphragm cover, then fasten the manual override to the diaphragm cover.
2. For DR40 actuators: Mount the diaphragm cover to the spring case with screws, nuts, and
washers. Place the caution tag and washer under one of the screws. Tighten the screws evenly
until the rubber diaphragm is in contact with the cover and the spring case. Then tighten the
screws in a crisscross pattern to 80 ± 2 inch pounds (9.0 ± 0.2 Nm).
For DR55 and DR85 actuators: Mount the diaphragm cover to the spring case with screws,
nuts and washers. Place the caution tag and washer under one of the screws. Tighten the
screws evenly until the rubber diaphragm is in contact with the cover and the spring case. Then
tighten the screws in a crisscross pattern to 12 ± 2 foot pounds (16 ± 3 Nm) for the DR55, or
18 ± 2 foot pounds (24 ± 3 Nm) for the DR85.
3. Connect the actuator piping.
4. Pipeline flow may now be restored.