Aqua Lung Legend First Stage Руководство по техническому обслуживанию - Страница 13
Просмотреть онлайн или скачать pdf Руководство по техническому обслуживанию для DJ оборудование Aqua Lung Legend First Stage. Aqua Lung Legend First Stage 18 страниц.
Legend First Stage Technical Maintenance Manual
PART # DESCRIPTION
Open-end Wrench
(1/", 9/16", 5/8")
(6mm, 3mm)
N/A
N/A
15" Adjustable Wrench
Crowfoot
(6mm, 3mm)
N/A
(1/", 9/16", 5/8")
N/A
Magnifier w/Illumination
N/A
Ultrasonic Cleaner
900014
Service Kit LEGEND
TEST
Leak Test
MP
MP creep
Table 2: List of Tools and Service Kits
Table 3: Torque Specifications
PART #
DESCRIPTION / KEY ITEM #
191
Spring Retainer (1)
1914
Inlet Fitting (30)
1460
DIN Connector (38)
1910
HP Plug (1)
19118
HP Port Plug (15) or hose
19119
MP Port Plug (17) or hose
19194
Cap (9)
19196
Table 4: Checking Specifications
CONDITION
Inlet ,500-3,000 (±100) psi
Inlet ,500-3,000 (±100) psi
Inlet ,500-3,000 (±100) psi
APPLICATION
Loosen/tighten/adjust parts
Loosen parts
Apply torque to parts listed in
Table 3: Torque Specification, p. 13
Sealing surface and spring inspection
Brass & stainless steel parts cleaning
SPECIFICATION
No leaks allowed
137±7 psi (standard)
13±7 psi (supreme)
5 psi max between 5 to 15 seconds
after cycling regulator (purge)
TORQUE
18 ft/lbs
18 ft/lbs
18 ft/lbs
45 in/lbs
40 in/lbs
40 in/lbs
35 in/lbs
13