Installation
requirements.
— Components for Billi Sahara
310, 320, 360 & 3120 Models
Before commencing installation,
ensure you have identified the following.
1. Underbench module
2. Dispenser upper with tubing
3. Dispenser base & mount
4. Barb locking bush
5. 4mm chrome screw & allen key
6. Large washer
7. Tube spring clamps x 3
8. 450mm flexible braided hose
10. Behind door panel:
a. filter cartridge
b. user guide
c. warranty registration card
11. Ensure a Stop Tap is installed 450mm
from the Billi unit water supply inlet
(Stop Tap not supplied)
—Determine Unit Location
Plan the installation. Dispenser tube lengths,
position of power and water outlets, required
air space around the underbench module and
access for service must be considered before
cutting tube lengths. Refer to Diagrams 1 and 2.
Unit must be installed horizontally with display
panel facing to front of cupboard. The Sahara is
designed for internal installation only.
Model
Height
Width
Sahara 310
340mm 180mm 365mm 10mm
Sahara /
Sahara Plus
340mm 180mm 460mm 10mm
320, 360, 3120
—Water Supply
The Sahara must only be connected to a cold
water supply. A 15mm stop tap (not supplied)
is to be installed in an easily accessible position
within 450mm from the Sahara water
supply inlet.
Dynamic water supply pressure:
Min. 250 Kpa, max. 1000 Kpa. (excludes
Sahara 310*)
Minimum water supply: 6 l/m at 250 Kpa
Supply temp: min. 5°C, max. 30°C.
* Sahara 310 supply pressure: Min 200 Kpa - 500Kpa.
Where supply pressure is greater than 500 Kpa a
PLV must be fitted. Billi recommends PLV's with
anti-hammer properties.
Do not install with water that is
microbiologically unsafe or with water of
unknown quality without adequate disinfection
before or after the system. Systems certified
for cyst reduction may be used on disinfected
water that may contain filterable cysts.
—Power Requirements
A single 13 amp standard power outlet is
required (15amp for Sahara 3120 & Sahara
3120 Plus). All Sahara modes are supplied
with a 1 metre flex cord and plug.
2
Min side
Depth
clearance
Power
Outlet
Cupboard Dimensions:
800mm
230mm Minimum Width
Tube Length
523mm Minimum Depth
Supplied
Stop Tap
(Installed by Plumber)
Max 450mm from Unit
20mm
175mm
205mm
10mm
bench
thickness
1mm-48mm
35mm
95mm
60mm
Minimum
Clearance
Diagram 1
130mm
Diagram 2