LIGHTING INSTRUCTIONS (Manual Control)
Lighting pilot
(For G15, G24, G36, G48 Models)
The pilot light on the appliance has been set at the factory. A screwdriver may be required for the
first lighting to adjust the flame for your elevation.
1. Turn off the manual valve and wait 5 minutes to clear the gas.
2. Turn all knobs to the "OFF" position.
3. Hold an ignition source (match) at the pilot. When the flame is established, remove the
ignition source.
4. Turn the burner knobs to "ON". If the burner does not ignite, promptly open the pilot valve
more. If the pilot flame appears larger than necessary, turn it down and reset burner ignition. The
pilot flame should be as small as possible but large enough to guarantee reliable ignition of the
burners when the knobs are turned to "ON".
Lighting main burner
(For G15, G24, G36, G48 Models)
To light burner, turn knob to "ON." Then adjust to the desired flame level. The range of adjustment
is virtually infinite between "ON" and "OFF".
Main burner air supply:
1. For efficient burner operation, a proper balance of gas volume and primary air supply must be
maintained which will result in complete combustion. Insufficient air supply results in a yellow
streaming flame. Primary air supply is controlled by an air shutter on the front of the burner.
2. Loosen the screws on the front of the burner and adjust the air shutter to just eliminate the
yellow tips of the burner flame. Lock the air shutter in place by tightening the screws.
Lighting the Main Burners
(For G15T, G24T, G36T, G48T Models)
These Griddles are fitted with individual standing pilots for each burner.
Flame Failure Protection is incorporated for each burner by way of a thermo-electric system which
will shut off the gas supply to that burner in the event that the burner goes out, so that un-burnt
gas is not expelled.
a. Select the burner required, depress and turn the corresponding gas control knob anti-clockwise
to the 'PILOT' position.
b. With the gas control knob depressed, manually light the pilot burner.
c. Release the gas control knob after approximately 10-20 seconds after lighting the pilot burner.
d. The pilot burner should stay alight - if not, repeat Steps (b. to c. above.)
e. Rotate the gas control knob anti-clockwise to the desired temperature mark.
f. The main burner will be now ignited automatically.
6