Avtron AV685 Инструкции - Страница 3
Просмотреть онлайн или скачать pdf Инструкции для Медиаконвертер Avtron AV685. Avtron AV685 4 страницы.
WIRING CONSIDERATIONS
For bidirectional operation of the SHAFTach™,
proper phasing of the two output channels is
important. Phase A channel leads phase B
channel for clockwise rotation as viewed from
the end-cap (anti-drive) end of the generator.
Interconnecting cables specified in the wiring
diagrams are based on typical applications.
Refer to the system drawing for specific cable
requirements where applicable.
Physical properties of cable such as abrasion,
temperature, tensile strength, solvents, etc.,
are dictated by the specific application. Gen-
eral electrical requirements are: stranded cop-
per, 22 thru 16 gauge, braid or foil with drain
wire, 0.05 MF maximum total mutual or direct
capacitance, outer sheath insulator, 1,000 ft.
max.
ENVIRONMENTAL
CONSIDERATIONS
Special attention is to be given to conduit runs, interconnection
wiring and NEMA type enclosure mounting. In those applications
where ambient temperatures are controlled within 40°F and high
humidity/washdown are not present, position the flexible conduit
with a slight sag to prevent any condensation from entering the
SHAFTach via conduit.
In harsh environments, which include temperature extremes, high
humidity, equipment washdown or atmosphere contamination,
extra care is required for interconnection. Follow these steps to
reduce potential problems:
OPERATING POWER (EACH OUTPUT) ...................................
OUTPUT SIGNAL ......................................................................
PULSES PER REVOLUTION.....................................................
WAVE SHAPE ............................................................................
VOLTAGE OUTPUT ....................................................................
OUTPUT PROTECTION ............................................................
FREQUENCY .............................................................................
MECHANICAL
SHAFT DIAMETER REQUIREMENTS ....................................
SPEED RANGE .......................................................................
STARTING TORQUE ................................................................
HUB INERTIA. ..........................................................................
ACCELERATION (MAX.) ..........................................................
OPERATING TEMPERATURE ...................................................
WEIGHT .....................................................................................
FOR SINGLE ENDED APPLICATIONS
OUTPUT OPTIONS
N
M585
RED
BLUE
GREEN
BLACK
FOR DIFFERENTIAL APPLICATIONS
BLACK
M585
RED
GREEN
YELLOW
BLUE
GRAY
M585WD.MAC
NOTE: 5' FLEXIBLE CONDUIT STANDARD
FOR ALL OUTPUT OPTIONS
1.
Always mount connection points, conduit couplings, junc-
tion boxes, etc., lower than actual generator.
2.
Venting of generator is beneficial. One method is to take
conduit run outside of hostile area where practical. (Applies to
conduit installations only.)
3.
For washdown areas, shroud or otherwise cover the
SHAFTach to prevent direct water spray. Do not attach the shroud
directly to the generator.
4.
Keep conduit outputs and axis of rotation horizontal.
5.
Purging of SHAFTach should be reviewed with Avtron.
M585 SPECIFICATIONS
15 V OPERATING VOLTAGE
12 TO 15 VDC AT APPROX. 70 mA (NO LOAD)
TWO CHANNELS IN QUADRATURE
(2-PHASE, BIDIRECTIONAL)
240, 360, 600, 1024, 1200, 2048 PPR STD.
— OTHERS AVAILABLE UPON REQUEST
SQUARE WAVE
HIGH:
SUPPLY VOLTAGE MINUS 1 VOLT
(NO LOAD)
120 OHMS PULL-UP
LOW:
1.0 VOLT MAX.
50mA SINK
SHORT CIRCUIT PROTECTION TO COMMON
50 KHz MAX.
1.125 +.000/-.003 INCHES
0 TO 3600 RPM
3.9 OZ.-IN. (TYP.)
0.5 OZ.-IN.-SEC
2
3000 RPM/SEC
0° TO 160°F AMBIENT
15 LBS.
WIRING DIAGRAM
C
T
FOR SINGLE ENDED
APPLICATIONS
B
+V
E
B
D
A
A
COM
CABLE BELDEN #8723
OR EQUIVALENT
FOR DIFFERENTIAL
APPLICATIONS
A
COM
B
+V
D
A
G
A
E
B
H
B
CABLE BELDEN #9773
OR EQUIVALENT
24 V OPERATING VOLTAGE
24 VDC AT APPROX. 70 mA (NO LOAD)
TWO CHANNELS IN QUADRATURE
(2-PHASE, BIDIRECTIONAL)
240, 360, 600, 1024, 1200, 2048 PPR STD.
— OTHERS AVAILABLE UPON REQUEST
SQUARE WAVE
HIGH:
SUPPLY VOLTAGE MINUS 1 VOLT
(NO LOAD)
330 OHMS PULL-UP
LOW:
1.0 VOLT MAX.
50mA SINK
SHORT CIRCUIT PROTECTION TO COMMON
50 KHz MAX.
1.125 +.000/-.003 INCHES
0 TO 3600 RPM
3.9 OZ.-IN. (TYP.)
0.5 OZ.-IN.-SEC
3000 RPM/SEC
0° TO 160°F AMBIENT
15 LBS.
FUNCTION
OPERATING
VOLTAGE
0B
0A
COMMON
GROUND
COMMON
OPERATING
VOLTAGE
0A
0A
0B
0B
GROUND
2