4
Remove Front Cover
Use the anti-theft wrench
to loosen the anti-theft
screw in the bottom part.
Security Screw
5
Remove Filters
Activated Carbon Filter
Take out the activated
carbon filter and remove any
protective packaging.
6
Install Gromet & Small Bracket
Trim the gromet to a moderate
size. Install the trimmed gromet
to the small bracket.
7
Attach Protection Bracket to Device
With the back of the
device facing up, install the
protection bracket. Snap the
buckles on the protection
bracket to the slots on the
back of the device.until there
is no sense of wobble. At this
point, installation of this part
is complete, as shown in the
figure above.
Slots
13
Lift the bottom up and
gently push up to remove
the complete cover.
HEPA Filter
Take out the HEPA filter
and remove any protective
packaging.
Install the protruding side of
it into the power cable hole
on the back of the device.
Install the unit with the
tapping screws to fix it.
Protection Bracket
Buckles
8
Install the HEPA & AC filters
Tear off the
package of the
HEPA filter and
insert it to the unit.
9
Remove Power Supply Cover
Power Supply Cover
Loosen the screw on the
cover of the power supply
unit and take off the cover.
10
Secure Device to ADA Compliance Kit
Insert the bottom of the
protection bracket into the
slots at the bottom of the
ADA compliance kit.
Insert AC filter into the
unit box, then insert the
unit box into the device.
Attach the chain included with
the ADA compliance kit to the
top rear slot of the protection
bracket of the device.
14