Ensure that the power cable is not damaged.
3
If the cable is damaged, use the spare power cable from the parts kit.
Connect the hard drive SCSI interface and power cables to the server module board.
4
See Figure 1-5.

Installing Memory Modules

CAUTION: See your System Information Guide for complete information about
safety precautions, working inside the computer, and protecting against
electrostatic discharge.
Locate the memory module connectors in which you will install a memory module.
1
See Figure 1-5.
Press down and outward on the ejectors, as shown in Figure 1-6, to allow the memory
2
module to be inserted into the connector.
Align the notch in the memory module's edge connector with the alignment key in the
3
socket, and insert the memory module in the connector. See Figure 1-6.
The memory module connector has an alignment key that allows the memory module
to be installed in the connector in only one way.
Press down on the memory module with your thumbs while pulling up on the ejectors
4
with your index fingers to lock the memory module into the connector. See Figure 1-6.
When the memory module is properly seated in the connector, the ejectors should
align with the ejectors on the other connectors with memory modules installed.
Repeat step 1 through step 4 of this procedure to install the remaining memory
5
module.

Closing the Server Module

CAUTION: See your System Information Guide for complete information about
safety precautions, working inside the computer, and protecting against
electrostatic discharge.
Insert the tabs on the left side of the server module into the slots on the right side of
1
the server module and rotate the sides up. See Figure 1-3 and Figure 1-4.
Slide the left side of the server module forward approximately 12.7 mm (0.5 inch). See
2
Figure 1-3.
Using a #2 Phillips screwdriver, tighten the two captive screws that secure the front
3
panel to the server module. See Figure 1-3.
1-14
Repl aci ng the S er v er Mo dule Bo ard