Dell PowerEdge 4350 Руководство по обновлению - Страница 21
Просмотреть онлайн или скачать pdf Руководство по обновлению для Сервер Dell PowerEdge 4350. Dell PowerEdge 4350 24 страницы. Dell poweredge 4350 system upgrade installation guide
Также для Dell PowerEdge 4350: Установка стойки (35 страниц), Руководство по обновлению (23 страниц), Руководство по установке (34 страниц), Руководство пользователя (35 страниц)
support.dell.com
To install an upgrade microprocessor, perform the following steps:
1.
Insert the new microprocessor into the system board connector (see
Figure 1-8).
2.
Press the microprocessor firmly into its connector until it is fully seated and the
latches snap into place.
You must use up to 25 lb of force to fully seat the microprocessor.
For Pentium III microprocessors, you do not need to change the jumper settings
on the system board.
For Pentium II microprocessors, set the speed jumper to the speed of the
microprocessor.
Upgrade microprocessors have a heat sink with a notch for engaging a threaded
stud on the system board, as shown in Figure 1-8.
3.
Repeat steps 1 and 2 for your second upgrade microprocessor or to install a
terminator card.
install this retention
pin after the cooling
shroud is installed
on PowerEdge 2300
systems only
threaded stud
,
'
!
Dell PowerEdge Systems — Microprocessor Upgrade
1-17