Allied Telesis AT-9800 Series Примечание к выпуску - Страница 2

Просмотреть онлайн или скачать pdf Примечание к выпуску для Программное обеспечение Allied Telesis AT-9800 Series. Allied Telesis AT-9800 Series 5 страниц. How to set up pppoe between a linux client and access concentrator
Также для Allied Telesis AT-9800 Series: Как настроить (9 страниц), Руководство по быстрой установке (12 страниц), Как сделать (8 страниц)

Allied Telesis AT-9800 Series Примечание к выпуску
2
Enabling and installing this Release
Some of the issues addressed in this Release Note include a level number. This
number reflects the importance of the issue that has been resolved. The levels
are:
This issue will cause significant interruption to network services, and
Level 1
there is no work-around.
Level 2
This issue will cause interruption to network service, however there
is a work-around.
Level 3
This issue will seldom appear, and will cause minor inconvenience.
This issue represents a cosmetic change and does not affect network
Level 4
operation.
Enabling and installing this Release
To use this maintenance release you must have a base release license for
Software Release 2.7.3. Contact your distributor or reseller for more
information.
To enable this release and install it as the preferred release, use the commands:
enable rel=sb273-01.rez num=2.7.3
set install=pref rel=sb273-01.rez
Features in sb273-01
sb273-01.rez includes the following issues resolved and enhancements
released:
Level 1
CR00005227
Module: SWI, RSTP, SWMX,
SWCX, SW56
A heavy processor load could lead to queuing RSTP BPDUs, which in turn
could lead to even more processor load, resulting in more queued BPDUs.
This issue has been resolved by improving the efficiency in the interaction
between RSTP TCN BPDUs and the hardware tables.
This issue has been resolved. (PCR number: 40672)
CR00006609
Module: LB
When failover occurred between a redundant pair of Load Balancing
devices, host ARP caches were not updated with the new Master's MAC
address, thus causing the hosts to lose connectivity until their ARP caches
timed out the stale entry.
Software Maintenance Release Note
Level: 1
Level: 1
This issue has been resolved.
(No PCR number.)
Release sb273-01
C613-10436-00 Rev A