Dell PowerEdge R320 Руководство по началу работы - Страница 8

Просмотреть онлайн или скачать pdf Руководство по началу работы для Сервер Dell PowerEdge R320. Dell PowerEdge R320 9 страниц. Poweredge series
Также для Dell PowerEdge R320: Руководство (11 страниц), Руководство по началу работы (11 страниц), Технические характеристики (2 страниц), Руководство по портфолио (27 страниц), Руководство по началу работы (9 страниц)

Dell PowerEdge R320 Руководство по началу работы
Environmental
NOTE: For additional information about environmental measurements for specific system configurations, see
dell.com/environmental_datasheets.
Temperature
Operating
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
Airborne Contaminant Level
Class
8
Continuous operation: 10 °C to 35 °C at 10% to 80% relative humidity
(RH), with 26 °C max dew point. De-rate maximum allowable dry bulb
temperature at 1 °C/300 m above 900 m (1°F per 550 ft).
NOTE: For information on supported expanded operating
temperature range and configurations, see support.dell.com/
manuals.
–40 °C to 65 °C (–40 °F to 149 °F) with a maximum temperature
gradation of 20 °C per hour
20% to 80% (noncondensing) at a maximum wet bulb temperature of 29
°C (84.2 °F)
5% to 95% at a maximum wet bulb temperature of 38 °C (100.4 °F)
0.26 G
at 5 Hz to 350 Hz (all operation orientations)
rms
1.87 G
at 10 Hz to 500 Hz for 15 min (all six sides tested)
rms
One shock pulse in the positive z axis (one pulse on each side of the
system) of 31 G for 2.6 ms in the operational orientation
Six consecutively executed shock pulses in the positive and negative x,
y, and z axes (one pulse on each side of the system) of 71 G for up to 2
ms
Six consecutively executed shock pulses in the positive and negative x,
y, and z axes (one pulse on each side of the system) of 32 G faired
square wave pulse with velocity change at 270 inches/second (685
centimeters/second)
–15.2 m to 3048 m (–50 to 10,000 ft)
NOTE: In compliance with the requirements of the official Chinese
standards, the operating altitude for systems shipping in China is
in the range of –15.2 m to 2000 m (–50 ft to 6560 ft).
NOTE: For altitudes above 2950 ft, the maximum operating
temperature is derated 1 ºF/550 ft.
–15.2 m to 10,668 m (–50 ft to 35,000 ft)
G1 as defined by ISA-S71.04-1985