POSSIBLE CAUSE
6
A. On logs, in fi rebox, or room
B. Drafts in room
C. Air shutters blocked (if applicable)
D. Log placement
E. Using natural-gas burner on propane gas or
propane burner on natural gas
F. Adding any accessories to log sets
7
A. Valve won't hold
B. Pilot hood not aimed at thermocouple
C. Pilot line bent
D. Thermocouple is loose
E. Thermocouple cracked or worn out
F. Excessive down draft
TROUBLESHOOTING (Cont.)
SOOTING
A. Check gas pressure (check with local gas company).
B. Eliminate drafts by closing heating and air conditioning
vents, returns, and outside air vents. Fans blowing directly
into fi replace should be turned off when set is operating.
C. Air shutters are blocked with debris. Vacuum debris away
from air shutter.
D. See solution in troubleshooting 1B.
E. If the gas listed on the nameplate does not match the gas
you are burning, shut down the burner system immediately
and completely (including pilot) following the steps in
the LIGHTING INSTRUCTIONS section. Then call your
dealer.
F. Shut down log set and take off any logs or accessories that
do not belong with the set.
PILOT WILL NOT STAY LIT
A. Contact your dealer for instructions on replacement.
B. Pilot hood bent; replace pilot or angle pilot hood properly so
pilot fl ame hits thermocouple.
C. Replace pilot line.
D. Tighten thermocouple nut at gas control valve.
E. Replace thermocouple.
F. Install chimney cap / Outside chimney too close to other
peaks / Check chimney fl ue for proper height / Poorly
designed chimney
16
SOLUTIONS