Allied Telesis Converteon AT-CV5000 Информационный лист - Страница 2

Просмотреть онлайн или скачать pdf Информационный лист для Программное обеспечение Allied Telesis Converteon AT-CV5000. Allied Telesis Converteon AT-CV5000 2 страницы. 18 slot converteon chassis media converters
Также для Allied Telesis Converteon AT-CV5000: Информационный лист (3 страниц), Информационный лист (1 страниц)

Allied Telesis Converteon AT-CV5000 Информационный лист
AT -CV5000
| 18 Slot Converteon Chassis
Technical Specifications
Status Indicators
LED
State
Description
RDY (For future use)
Green
The module installed in
the rear expansion slot has
passed diagnostics and is
ready.
Off
The module installed in
the rear expansion slot has
failed diagnostics and is
not ready, or is not
installed.
MSTR (for future use)
Green
This AT-CV5000 chassis is
acting as a stacking master
(via a module installed in
the rear expansion slot).
Off
This AT-CV5000 chassis is
not a stacking master.
FLT (for future use)
Green
The module installed in
the rear expansion slot has
experienced fault condition,
or is not installed.
Off
The module installed in
the rear expansion slot has
reported no fault
condition.
PS-A
Green
Power supply in slot A is
operating normally.
Off
Power supply in slot A is
OFF, not present, or has
failed.
PS-B
Green
Power supply in slot B is
operating normally.
Off
Power supply in slot B is
OFF, not present, or has
failed.
FAN-A
Green
Fan module in fan tray
slot A is operating
normally.
Off
Fan module in fan tray
slot A is OFF, not present,
or has failed.
FAN-B
Green
Fan module in fan tray
slot B is operating
normally.
Off
Fan module in fan tray
slot B is OFF, not present,
or has failed.
USA Headquarters
|
19800 North Creek Parkway
European Headquarters
|
Via Motta 24
Asia-Pacific Headquarters
|
11 Tai Seng Link
www.alliedtelesis.com
© 2007 Allied Telesis Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners.
Connectors
The front panel features an RS232 (DB9) connector,
which will be used to provide connectivity to a rear
mounted expansion card in the future.

Physical Specifications

Dimensions:
(W x D x H)
Weight:
Power Characteristics
AC input voltage:
AC input current:

Environmental Specifications

Maximum operating
temperature:
Maximum storage
temperature:
Operating and
storage altitude:
Relative humidity
operating:
Relative humidity storage: 5% to 95% non-condensing
Predicted MTBF (Telcordia SR332): 64,000 hrs
Standards
EMI part 15:
FCC class A, EN55022 class A, VCCI class A, C-Tick, CE
Immunity:
EN55024
Safety:
UL60950-1 (cULUS), EN60950-1 (TUV)
|
Suite 200
|
Bothell
|
6830 Chiasso
|
Switzerland
|
T: +41 91 69769.00
|
Singapore
|
534182
|
T: +65 6383 3832
34.25cm x 44.05cm x 8.68cm
(13.49" x 17.35" x 3.42")
7.5kg (16.6lbs) w/o P/S
90 ~ 240V AC 47/63Hz
90-120V AC (3.6A)
200-240V AC (1.57A)
0°C to 40°C
(32°F to 104°F)
-25°C to 70°C
(-13°F to 158°F)
Up to 3,048 meters
(10,000 feet)
5% to 90% non-condensing
|
WA 98011
|
USA
|
T: +1 800 424 4284
|
F: +41 91 69769.11
|
F: +65 6383 3830

Ordering Information

AT-CV5000-00
18-slot AC chassis with no power supply
AT-PWR14
AC redundant power module for AT-CV5000 chassis
Associated Products
AT-CVFAN
Replacement fan module for AT-CV5000 chassis
AT-CV5M01
SNMP management module for AT-CV5000 chassis
AT-CV1000-xx
Single slot Converteon chassis
AT-CV1203-xx
Two slot Converteon chassis
|
F: +1 425 481 3895
617-000143 Rev.H