Replacing SC7020 Storage System
Components
This section describes how to remove and install components of the SC7020 storage system.
This information assumes that you have received the replacement component and are ready to install it.
Safety Precautions
Always follow these safety precautions to avoid injury and damage to Storage Center equipment.
If equipment described in this section is used in a manner not specified by Dell, the protection provided
by the equipment could be impaired. For your safety and protection, observe the rules described in the
following sections.
NOTE: See the safety and regulatory information that shipped with each Storage Center
component. Warranty information is included within this document or as a separate document.
Installation Safety Precautions
Follow these safety precautions:
•
Dell recommends that only individuals with rack-mounting experience install the SC7020 in a rack.
•
Make sure the storage system is always fully grounded to prevent damage from electrostatic
discharge.
•
When handling the storage system hardware, use an electrostatic wrist guard (not included) or a
similar form of protection.
The chassis must be mounted in a rack. The following safety requirements must be considered when the
chassis is being mounted:
•
The rack construction must be capable of supporting the total weight of the installed chassis. The
design should incorporate stabilizing features suitable to prevent the rack from tipping or being
pushed over during installation or in normal use.
•
To avoid danger of the rack toppling over, slide only one chassis out of the rack at a time.
Electrical Safety Precautions
Always follow electrical safety precautions to avoid injury and damage to Storage Center equipment.
•
Provide a suitable power source with electrical overload protection. All Storage Center components
must be grounded before applying power. Make sure that a safe electrical earth connection can be
made to power supply cords. Check the grounding before applying power.
•
The plugs on the power supply cords are used as the main disconnect device. Make sure that the
socket outlets are located near the equipment and are easily accessible.