Identifying the Failed Cooling Fan
To determine which cooling fan failed, use the Dell Storage Client.
1.
Click the Hardware tab.
2.
In the Hardware tab navigation pane, select the Storage Center.
3.
In the Hardware Alerts area, find the hardware alert that identifies the enclosure with the failed
cooling fan.
Figure 12. Hardware Alert Identifying the Enclosure with the Failed Cooling Fan
4.
In the Hardware tab navigation pane, expand the enclosure identified in the previous step.
5.
Select Cooling Fan Sensors. The status of each cooling fan is displayed in the Cooling Fans tab.
6.
Select the failed cooling fan. The location of the failed cooling fan is displayed in the Cooling Fan
View tab.
22
Replacing SCv2000/SCv2020 Components