Dell Storage MD1400 series Руководство пользователя - Страница 28
Просмотреть онлайн или скачать pdf Руководство пользователя для Хранение Dell Storage MD1400 series. Dell Storage MD1400 series 37 страниц. Storage enclosure
Также для Dell Storage MD1400 series: Руководство по началу работы (7 страниц), Руководство администратора (48 страниц)
Technical specifications
NOTE: The following specifications are only those required by law to ship with your system. For a
complete and current listing of the specifications for your system, go to dell.com/support.
Power
AC Power Supply (per power supply)
Watt
Heat dissipation
NOTE: Heat dissipation is calculated
using the power supply wattage
rating.
Voltage
NOTE: This system is also designed
to be connected to IT power systems
with a phase to phase voltage not
exceeding 230 V.
DC Power Supply (per power supply)
Watt
Heat dissipation
NOTE: Heat dissipation is calculated
using the power supply wattage
rating.
Voltage
Temperature
Maximum operation ambient temperature
For information about supported expanded operating temperature range and configurations, see
dell.com/support/manuals.
Control panel
Removing the control panel
1.
Turn off the enclosure and host server.
2.
Disconnect all the power cables connected to the enclosure.
3.
Remove the hard disk drives from slot 0 to 2. See
4.
Slide the control panel out of the chassis after pushing the release tab toward the front of the
enclosure.
28
600 W
2047 BTU/hr (redundant, 600 W power supply)
100–240 V AC, autoranging, 50/60 Hz
700 W
2388 BTU/hr (redundant, 700 W power supply)
–(48–60) V DC
35° C
Removing a hard disk
drive.