Set the IP address for RPM 1:
Dell(conf)#interface ManagementEthernet 1/0
Dell(conf-if-ma-1/0)#ip address <ipaddress> <mask>
Dell(conf-if-ma-1/0)#no shutdown
Dell(conf-if-ma-1/0)#exit
Set the virtual IP address:
Dell(conf)#virtual-ip <ipaddress> <mask>
2.4

Configure route for OOB management port (optional)

Dell(conf)#management route X.Y.Z.0 /24 A.B.C.1
X.Y.Z.0
Note:
the switch. If your management system is on the same subnet as the switch, the previous step may be
omitted. The example above assumes a class C subnet mask.
2.5

Configure login credentials

Dell(conf)#username admin privilege 15 password 0 yourpassword
Dell(conf)#enable password level 15 0 yourpassword
2.6

Enable switch ports

Option 1: Enable ports individually by entering the port number.
Dell(conf)#interface tengigabitethernet 0/0
Dell(conf-if-te-0/0)#switchport
Dell(conf-if-te-0/0)#exit
Dell(conf)#exit
Option 2: Enable multiple ports at once using the 'range' parameter.
Note: This example configuration shows details for configuring linecards 0 and 1. Use the proper port
range for your SAN environment.
Dell(conf)#interface range tengigabitethernet 0/0–23 , tengigabitethernet 1/0–23
Dell(conf-if-range-te-0/0-23,te-1/0-23)#switchport
2.7

Enable Jumbo Frames

Dell(conf-if-range-te-0/0-23,te-1/0-23)#mtu 12000
7
SCG2011
Dell Networking C9000 Series Switch Configuration Guide for Dell SC Series SANs
is the network your management system is connecting from and
A.B.C.1
is the gateway for