Table 11. Environmental Parameters (continued)
Parameter
Maximum operational altitude
Maximum non-operational altitude
Shock
Table 12. AC power requirements
Parameter
Power Supply
Maximum Current Draw Per System
PSU Maximum Power Capability
Typical and Maximum Power Consumption
Reliability
Table 13. DC power requirements
Parameter
PSU Maximum Power Capability
PSU Maximum current required
Minimum and maximum input voltage range
Input power at full load
Input current at full load
Start up VDC
Start off VDC
IEEE standards
The S6100–ON complies with the following IEEE standards:
● 802.3ab Gigabit Ethernet (1000BASE-T)
● 802.3ae 10 Gigabit Ethernet (10GBASE-X)
● 802.3ba 40 Gigabit Ethernet (40GBase-SR4, 40GBase-CR4) on optical ports
● 802.3ba 100 Gigabit Ethernet
● 802.3bj 100 Gigabit Ethernet
● 802.3bm 100 Gigabit Ethernet
44
Specifications
Specifications
10,000 feet (3,048 meters)
No performance degradation to 35,000 feet (10,668 meters)
SV0115 — ODM
Specifications
100–240 VAC 50/60 Hz
12A–6.5A @ 100–240 VAC
1100 Watts
343 Watts typical
896 Watts maximum
MTBF 1,154,397 hours
Specifications
1100 Watts
32A
−40.5 V / −48 V/ −60 V
−40.5 V/970 W −48 V/930 W −60 V/950 W, without fan
−40.5 V/980 W −48 V/940 W −60V/ 960 W, with fan
−40.5V/23.8A −48V/19.0A −60V/ 15.6A, without fan
−40.5V/24.0A −48V/19.2A −60V/ 16.0A, with fan
39.0+/−1.5 V
37.5+/−1.5 V