Dell EMC S5000 Руководство по установке - Страница 32

Просмотреть онлайн или скачать pdf Руководство по установке для Переключатель Dell EMC S5000. Dell EMC S5000 42 страницы.

Dell EMC S5000 Руководство по установке
Figure 24. Stacking Topology

Connecting Two S5000 Systems

To provide backup connectivity and increased data transfer between the systems, Dell EMC recommends inserting an additional cable
between the two units, in a second stacking port.
You can use any of the SFP+ or QSFP+ ports for stacking, provided it is configured as a stacking port.
CAUTION:
The S5000 does not require special stacking cables. The cables used to connect 10GbE and 40GbE data ports
are sufficient.
NOTE:
The port numbers in the following procedure are examples only.
1. Insert one end of the first cable into stack port 60 in chassis 1 (bottom).
2. Insert the other end of the same cable into stack port 60 on chassis 2 (top).
3. Insert a second cable into stack port 56 on chassis 2 (top).
4. Insert the other end of the second cable into stack port 56 on chassis 1 (bottom).
32
Installation