Flash Level — Limits log messages saved to the switch's permanent
flash memory for all levels up to the specified level. For example, if
level 3 is specified, all messages from level 0 to level 3 are logged to
flash.
•
Ram Level — Limits log messages that are saved to the switch's
temporary RAM memory for all levels up to the specified level. For
example, if level 7 is specified, all messages from level 0 to level 7 are
logged to RAM.
To save any changes you make in this page, click Apply Changes. If you do
not want to save the changes, click Refresh.
The following figure is representative of PowerConnect 3248 and 5224.
Addendum to the 3 248 and 52 24 User 's Guides
NOTE: The Flash Level
must be equal to or less
than the Ram Level.
NOTE: System log
messages are logged
every 60 minutes.